← Massachusetts

Tap water quality report

Boumil Grove Condos

EPA monitoring tested this supplier for 69 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
16
detected
72
people served
100
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Rockingham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

100
health-based violations
699
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-01-02
TT Health-based Resolved 2024-01-02
TT Health-based Resolved 2024-01-02
TT Health-based Resolved 2024-01-02
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
74 µg/L 5.7%
of the EPA limit 1300 µg/L
11/12 SYR4 2015–2018
Combined Radium (-226 And -228)
6.9 pCi/L 138%
of the EPA limit, in the worst sample — 5 pCi/L
9/9 SYR4 2014–2019
Combined Uranium
5 µg/L 17%
of the EPA limit 30 µg/L
7/7 SYR4 2017–2019
Gross Alpha, Excl. Radon And U
62.8 pCi/L 419%
of the EPA limit, in the worst sample — 15 pCi/L
7/7 SYR4 2017–2019
Lead
3.2 µg/L 21%
of the EPA limit 15 µg/L
6/11 SYR4 2015–2018
Arsenic
3 µg/L 30%
of the EPA limit 10 µg/L
2/2 SYR4 2015–2018
Barium
35 µg/L 1.8%
of the EPA limit 2000 µg/L
2/2 SYR4 2015–2018
Chloroform
1.3 µg/L
No EPA limit set
2/6 SYR4 2014–2019
Fluoride
1300 µg/L 33%
of the EPA limit 4000 µg/L
2/2 SYR4 2015–2018
TTHM
4.4 µg/L 5.5%
of the EPA limit 80 µg/L
2/4 SYR4 2014–2019
Toluene
1.8 µg/L 0.2%
of the EPA limit 1000 µg/L
2/11 SYR4 2014–2019
Bromodichloromethane
0.8000 µg/L
No EPA limit set
1/6 SYR4 2014–2019
Bromoform
1.1 µg/L
No EPA limit set
1/6 SYR4 2014–2019
Chromium
4 µg/L 4%
of the EPA limit 100 µg/L
1/2 SYR4 2015–2018
Dibromochloromethane
1.2 µg/L
No EPA limit set
1/6 SYR4 2014–2019
Mercury
0.1600 µg/L 8%
of the EPA limit 2 µg/L
1/2 SYR4 2015–2018
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNitrateNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
S JAMES/THOMAS BOUMIL

Frequently asked questions about Boumil Grove Condos

Is Boumil Grove Condos tap water safe to drink?

EPA monitoring detected 16 contaminants in Boumil Grove Condos's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Boumil Grove Condos's water?

EPA monitoring detected Copper, Combined Radium (-226 And -228), Combined Uranium, Gross Alpha, Excl. Radon And U, Lead, and others. The full list with the level and data source for each is above.

How many people does Boumil Grove Condos serve?

Boumil Grove Condos reports serving 72 people in Massachusetts, per its EPA record.

Has Boumil Grove Condos had any water quality violations?

The EPA has 699 violations on file for Boumil Grove Condos, of which 100 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.