← North Carolina

Tap water quality report

Broadhurst/Turner Downs S/D

EPA monitoring tested this supplier for 78 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
8
detected
597
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Wake

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
15
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
RPT Monitoring Resolved 2024-02-01
RPT Monitoring Resolved 2024-02-01
RPT Monitoring Resolved 2024-02-01
RPT Monitoring Resolved 2024-02-01
RPT Monitoring Resolved 2024-02-01
RPT Monitoring Resolved 2024-02-01
RPT Monitoring Resolved 2024-02-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Combined Radium (-226 And -228)
5.705 pCi/L 114%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 5.9 pCi/L
14/18 SYR4 2012–2019
Copper
116.46 µg/L 9%
of the EPA limit 1300 µg/L
worst single sample: 135 µg/L
10/30 SYR4 2013–2019
Fluoride
197.5 µg/L 4.9%
of the EPA limit 4000 µg/L
worst single sample: 200 µg/L
6/8 SYR4 2012–2018
Gross Beta Particle Activity
11.15 pCi/L
No EPA limit set
worst single sample: 11.6 pCi/L
6/6 SYR4 2012–2019
1,2-Dichloropropane
0.7900 µg/L 16%
of the EPA limit 5 µg/L
worst single sample: 0.8000 µg/L
5/14 SYR4 2012–2019
Combined Uranium
2.09047 µg/L 7%
of the EPA limit 30 µg/L
worst single sample: 2.1456 µg/L
3/6 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR 2025
TTHM
1 µg/L 1.3%
of the EPA limit 80 µg/L
1/10 SYR4 2013–2019
70 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLIRON, BRENT
Phone
919-653-6999
Email
bmilliron@aquaamerica.com

Frequently asked questions about Broadhurst/Turner Downs S/D

Is Broadhurst/Turner Downs S/D tap water safe to drink?

EPA monitoring detected 8 contaminants in Broadhurst/Turner Downs S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Broadhurst/Turner Downs S/D's water?

EPA monitoring detected Combined Radium (-226 And -228), Copper, Fluoride, Gross Beta Particle Activity, 1,2-Dichloropropane, and others. The full list with the level and data source for each is above.

How many people does Broadhurst/Turner Downs S/D serve?

Broadhurst/Turner Downs S/D reports serving 597 people in North Carolina, per its EPA record.

Has Broadhurst/Turner Downs S/D had any water quality violations?

The EPA has 15 violations on file for Broadhurst/Turner Downs S/D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.