Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2024-07-01 |
| Other | Monitoring | Resolved | 2024-07-01 |
| Other | Monitoring | Resolved | 2024-07-01 |
| Other | Monitoring | Resolved | 2008-02-01 |
| Other | Monitoring | Resolved | 2008-02-01 |
| MR | Monitoring | Resolved | 2006-07-01 → 2006-09-30 |
| MR | Monitoring | Resolved | 2006-07-01 → 2006-09-30 |
| MR | Monitoring | Resolved | 2006-07-01 → 2006-09-30 |
| Other | Monitoring | Resolved | 2002-07-01 |
| Other | Monitoring | Resolved | 2002-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 547 µg/L 42% of the EPA limit 1300 µg/L
worst single sample: 697 µg/L | 21/27 | SYR4 | 2012–2019 |
| Fluoride | 259 µg/L 6.5% of the EPA limit 4000 µg/L
worst single sample: 280 µg/L | 8/9 | SYR4 | 2013–2018 |
| Lead | 16.0855 µg/L 107% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18.1 µg/L | 4/27 | SYR4 | 2012–2019 |
| Nitrate | 1400 µg/L 14% of the EPA limit 10000 µg/L | 2/60 | SYR4 | 2012–2019 |
| Chloroform | 7.2 µg/L No EPA limit set | 1/2 | SYR4 | 2014–2017 |
| Dichloroacetic Acid | 1.1 µg/L No EPA limit set | 1/2 | SYR4 | 2014–2017 |
| Gross Beta Particle Activity | 5.4 pCi/L No EPA limit set | 1/8 | SYR4 | 2016–2018 |
| Lead | 0.0016 mg/L 11% of the EPA limit 0.0150 mg/L | 1/1 | LCR | 2025 |
| Nitrate-Nitrite | 1400 µg/L 14% of the EPA limit 10000 µg/L | 1/30 | SYR4 | 2012–2019 |
| TTHM | 7.2 µg/L 9% of the EPA limit 80 µg/L | 1/2 | SYR4 | 2014–2017 |
68 contaminants tested, none detected
Utility contact
Frequently asked questions about Sedgemoor S/D
Is Sedgemoor S/D tap water safe to drink?
EPA monitoring detected 10 contaminants in Sedgemoor S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Sedgemoor S/D's water?
EPA monitoring detected Copper, Fluoride, Lead, Nitrate, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Sedgemoor S/D serve?
Sedgemoor S/D reports serving 435 people in North Carolina, per its EPA record.
Has Sedgemoor S/D had any water quality violations?
The EPA has 11 violations on file for Sedgemoor S/D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.