← North Carolina

Tap water quality report

Sterlingshire S/D

EPA monitoring tested this supplier for 80 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
14
detected
201
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Guilford

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2008-06-14
MR Monitoring Resolved 2007-01-01
MR Monitoring Resolved 2007-01-01
MR Monitoring Resolved 2007-01-01
MR Monitoring Resolved 2007-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3690 µg/L 37%
of the EPA limit 10000 µg/L
30/32 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
8/8 LCR 2025
Nitrate-Nitrite
3300 µg/L 33%
of the EPA limit 10000 µg/L
7/8 SYR4 2012–2015
Ethylene Dibromide
0.0260 µg/L 52%
of the EPA limit 0.0500 µg/L
5/13 SYR4 2012–2019
Fluoride
240 µg/L 6%
of the EPA limit 4000 µg/L
4/5 SYR4 2012–2018
Copper
77 µg/L 5.9%
of the EPA limit 1300 µg/L
2/10 SYR4 2014–2017
Dibromoacetic Acid
1.8 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Dibromochloromethane
1.2 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Dichloroacetic Acid
8.2 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Gross Beta Particle Activity
4.5 pCi/L
No EPA limit set
1/1 SYR4 2017
Heptachlor Epoxide
0.1620 µg/L 81%
of the EPA limit 0.2000 µg/L
1/8 SYR4 2014–2019
TTHM
1.2 µg/L 1.5%
of the EPA limit 80 µg/L
1/4 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
12 µg/L 20%
of the EPA limit 60 µg/L
1/4 SYR4 2013–2019
Trichloroacetic Acid
3 µg/L
No EPA limit set
1/2 SYR4 2016–2019
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DYE, WESLEY
Phone
919-467-8712
Email
wadye@aquaamerica.com

Frequently asked questions about Sterlingshire S/D

Is Sterlingshire S/D tap water safe to drink?

EPA monitoring detected 14 contaminants in Sterlingshire S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sterlingshire S/D's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Ethylene Dibromide, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Sterlingshire S/D serve?

Sterlingshire S/D reports serving 201 people in North Carolina, per its EPA record.

Has Sterlingshire S/D had any water quality violations?

The EPA has 8 violations on file for Sterlingshire S/D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.