← North Carolina

Tap water quality report

Windstone Crossing

EPA monitoring tested this supplier for 79 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
11
detected
112
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Iredell

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
1
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2024-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Gross Beta Particle Activity
12.2 pCi/L
No EPA limit set
4/4 SYR4 2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
4/4 LCR 2025
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
3/4 SYR4 2019
Barium
2990 µg/L 150%
of the EPA limit, in the worst sample — 2000 µg/L
2/4 SYR4 2019
Chloroform
1.3 µg/L
No EPA limit set
1/1 SYR4 2019
Dibromoacetic Acid
1.6 µg/L
No EPA limit set
1/1 SYR4 2019
Dichloroacetic Acid
18 µg/L
No EPA limit set
1/1 SYR4 2019
Fluoride
590 µg/L 15%
of the EPA limit 4000 µg/L
1/1 SYR4 2019
TTHM
1.3 µg/L 1.6%
of the EPA limit 80 µg/L
1/1 SYR4 2019
Total Haloacetic Acids (HAA5)
32 µg/L 53%
of the EPA limit 60 µg/L
1/1 SYR4 2019
Trichloroacetic Acid
12 µg/L
No EPA limit set
1/1 SYR4 2019
68 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLIRON, BRENT
Phone
919-653-6999
Email
bmilliron@aquaamerica.com

Frequently asked questions about Windstone Crossing

Is Windstone Crossing tap water safe to drink?

EPA monitoring detected 11 contaminants in Windstone Crossing's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Windstone Crossing's water?

EPA monitoring detected Gross Beta Particle Activity, Lead, Combined Radium (-226 And -228), Barium, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Windstone Crossing serve?

Windstone Crossing reports serving 112 people in North Carolina, per its EPA record.

Has Windstone Crossing had any water quality violations?

The EPA has 1 violation on file for Windstone Crossing, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.