Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| MCL | Health-based | Resolved | 2011-01-01 → 2011-03-31 |
| MCL | Health-based | Resolved | 2011-01-01 → 2011-03-31 |
| MCL | Health-based | Resolved | 2011-01-01 → 2011-03-31 |
| MCL | Health-based | Resolved | 2011-01-01 → 2011-03-31 |
| MCL | Health-based | Resolved | 2010-10-01 → 2010-12-31 |
| MCL | Health-based | Resolved | 2010-10-01 → 2010-12-31 |
| MCL | Health-based | Resolved | 2010-10-01 → 2010-12-31 |
| MCL | Health-based | Resolved | 2010-10-01 → 2010-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 99.25 µg/L 124% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 111.8 µg/L | 52/52 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 49.65 µg/L 83% of the EPA limit 60 µg/L
worst single sample: 82.9 µg/L | 52/52 | SYR4 | 2012–2019 |
| Bromodichloromethane | 24.12 µg/L No EPA limit set
worst single sample: 26 µg/L | 45/45 | SYR4 | 2013–2019 |
| Chloroform | 60.82 µg/L No EPA limit set
worst single sample: 80.4 µg/L | 45/45 | SYR4 | 2013–2019 |
| Dibromochloromethane | 9 µg/L No EPA limit set
worst single sample: 12 µg/L | 45/45 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 24.58 µg/L No EPA limit set
worst single sample: 38.7 µg/L | 45/45 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 16.56 µg/L No EPA limit set
worst single sample: 40.6 µg/L | 45/45 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 2.58 µg/L No EPA limit set
worst single sample: 2.9 µg/L | 32/45 | SYR4 | 2013–2019 |
| Copper | 161.6 µg/L 12% of the EPA limit 1300 µg/L
worst single sample: 172 µg/L | 5/139 | SYR4 | 2014–2019 |
| Monochloroacetic Acid | 3.3 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 5/45 | SYR4 | 2013–2019 |
| Bromoform | 1 µg/L No EPA limit set | 4/45 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 1/1 | LCR | 2025 |
| Lead | 6 µg/L 40% of the EPA limit 15 µg/L | 1/139 | SYR4 | 2014–2019 |
1 contaminants tested, none detected
Utility contact
Frequently asked questions about Northampton--Gaston
Is Northampton--Gaston tap water safe to drink?
EPA monitoring detected 13 contaminants in Northampton--Gaston's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Northampton--Gaston's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Northampton--Gaston serve?
Northampton--Gaston reports serving 1,123 people in North Carolina, per its EPA record.
Has Northampton--Gaston had any water quality violations?
The EPA has 69 violations on file for Northampton--Gaston, of which 36 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.