Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2004-04-01 → 2004-06-30 |
| MCL | Health-based | Resolved | 2004-04-01 → 2004-06-30 |
| MCL | Health-based | Resolved | 2004-04-01 → 2004-06-30 |
| MCL | Health-based | Resolved | 2004-04-01 → 2004-06-30 |
| MCL | Health-based | Resolved | 1999-10-01 → 1999-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 4020 µg/L 40% of the EPA limit 10000 µg/L | 40/64 | SYR4 | 2012–2019 |
| Copper | 2151 µg/L 165% of the EPA limit, in the worst sample — 1300 µg/L | 26/30 | SYR4 | 2012–2018 |
| Combined Radium (-226 And -228) | 11.4 pCi/L 228% of the EPA limit, in the worst sample — 5 pCi/L | 19/31 | SYR4 | 2012–2019 |
| Combined Uranium | 9.4317 µg/L 31% of the EPA limit 30 µg/L | 6/21 | SYR4 | 2012–2019 |
| Lead | 5 µg/L 33% of the EPA limit 15 µg/L | 6/30 | SYR4 | 2012–2018 |
| Dibromochloromethane | 2.6 µg/L No EPA limit set | 4/7 | SYR4 | 2014–2019 |
| TTHM | 11 µg/L 14% of the EPA limit 80 µg/L | 4/7 | SYR4 | 2014–2019 |
| Bromodichloromethane | 3.8 µg/L No EPA limit set | 3/7 | SYR4 | 2014–2019 |
| Chloroform | 4.4 µg/L No EPA limit set | 3/7 | SYR4 | 2014–2019 |
| Fluoride | 640 µg/L 16% of the EPA limit 4000 µg/L | 3/10 | SYR4 | 2014–2017 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 3/3 | LCR | 2025 |
| Nitrate-Nitrite | 3000 µg/L 30% of the EPA limit 10000 µg/L | 2/4 | SYR4 | 2019 |
| Bromoform | 1 µg/L No EPA limit set | 1/7 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 1 µg/L No EPA limit set | 1/7 | SYR4 | 2014–2019 |
| Dichloroacetic Acid | 2.9 µg/L No EPA limit set | 1/7 | SYR4 | 2014–2019 |
| Gross Beta Particle Activity | 4.6 pCi/L No EPA limit set | 1/1 | SYR4 | 2017 |
| Total Haloacetic Acids (HAA5) | 3.9 µg/L 6.5% of the EPA limit 60 µg/L | 1/7 | SYR4 | 2014–2019 |
61 contaminants tested, none detected
Utility contact
Frequently asked questions about Sandy Trail S/D
Is Sandy Trail S/D tap water safe to drink?
EPA monitoring detected 17 contaminants in Sandy Trail S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Sandy Trail S/D's water?
EPA monitoring detected Nitrate, Copper, Combined Radium (-226 And -228), Combined Uranium, Lead, and others. The full list with the level and data source for each is above.
How many people does Sandy Trail S/D serve?
Sandy Trail S/D reports serving 739 people in North Carolina, per its EPA record.
Has Sandy Trail S/D had any water quality violations?
The EPA has 14 violations on file for Sandy Trail S/D, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.