← North Carolina

Tap water quality report

Tyndrum S/D

EPA monitoring tested this supplier for 78 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
12
detected
102
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Durham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1995-01-01
TT Health-based Resolved 1995-01-01
TT Health-based Resolved 1995-01-01
TT Health-based Resolved 1995-01-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2002-07-01
Other Monitoring Resolved 2002-07-01
Other Monitoring Resolved 2002-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1283.6 µg/L 99%
of the EPA limit 1300 µg/L
worst single sample: 3230 µg/L
17/20 SYR4 2012–2018
Fluoride
218 µg/L 5.5%
of the EPA limit 4000 µg/L
worst single sample: 220 µg/L
3/4 SYR4 2014–2017
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR 2025
Bromodichloromethane
4.6 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Bromoform
2.2 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Chloroform
2.8 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Dibromoacetic Acid
1.9 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Dibromochloromethane
6.8 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Dichloroacetic Acid
1.4 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Lead
4.16 µg/L 28%
of the EPA limit 15 µg/L
1/20 SYR4 2012–2018
TTHM
16 µg/L 20%
of the EPA limit 80 µg/L
1/4 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
3.3 µg/L 5.5%
of the EPA limit 60 µg/L
1/4 SYR4 2013–2019
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLIRON, BRENT
Phone
919-653-6999
Email
bmilliron@aquaamerica.com

Frequently asked questions about Tyndrum S/D

Is Tyndrum S/D tap water safe to drink?

EPA monitoring detected 12 contaminants in Tyndrum S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Tyndrum S/D's water?

EPA monitoring detected Copper, Fluoride, Lead, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Tyndrum S/D serve?

Tyndrum S/D reports serving 102 people in North Carolina, per its EPA record.

Has Tyndrum S/D had any water quality violations?

The EPA has 16 violations on file for Tyndrum S/D, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.