← North Carolina

Tap water quality report

Heather Glen S/D

EPA monitoring tested this supplier for 77 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
13
detected
255
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Durham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
760.2 µg/L 58%
of the EPA limit 1300 µg/L
worst single sample: 767 µg/L
18/20 SYR4 2012–2018
Nitrate
1250 µg/L 13%
of the EPA limit 10000 µg/L
16/64 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR 2025
Bromodichloromethane
4.665 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
2/2 SYR4 2014–2017
Bromoform
1.99 µg/L
No EPA limit set
worst single sample: 2 µg/L
2/2 SYR4 2014–2017
Chloroform
13.69 µg/L
No EPA limit set
worst single sample: 14.2 µg/L
2/2 SYR4 2014–2017
Dibromoacetic Acid
1.395 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
2/2 SYR4 2014–2017
Dibromochloromethane
5.57 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
2/2 SYR4 2014–2017
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
2/12 SYR4 2012–2019
TTHM
25.735 µg/L 32%
of the EPA limit 80 µg/L
worst single sample: 26.3 µg/L
2/2 SYR4 2014–2017
Total Haloacetic Acids (HAA5)
1.395 µg/L 2.3%
of the EPA limit 60 µg/L
worst single sample: 1.4 µg/L
2/2 SYR4 2014–2017
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
1/7 SYR4 2012–2018
Nitrate-Nitrite
1100 µg/L 11%
of the EPA limit 10000 µg/L
1/5 SYR4 2018–2019
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PATEL, HARSHNA
Phone
800-525-7990
Email
harshna.patel@nexuswg.com

Frequently asked questions about Heather Glen S/D

Is Heather Glen S/D tap water safe to drink?

EPA monitoring detected 13 contaminants in Heather Glen S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Heather Glen S/D's water?

EPA monitoring detected Copper, Nitrate, Lead, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Heather Glen S/D serve?

Heather Glen S/D reports serving 255 people in North Carolina, per its EPA record.

Has Heather Glen S/D had any water quality violations?

The EPA has 3 violations on file for Heather Glen S/D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.