Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 1994-01-01 |
| TT | Health-based | Resolved | 1994-01-01 |
| TT | Health-based | Resolved | 1994-01-01 |
| TT | Health-based | Resolved | 1994-01-01 |
| Other | Monitoring | Resolved | 2024-07-01 |
| Other | Monitoring | Resolved | 2002-07-01 |
| Other | Monitoring | Resolved | 2002-07-01 |
| Other | Monitoring | Resolved | 2002-07-01 |
| Other | Monitoring | Resolved | 2001-07-01 |
| Other | Monitoring | Resolved | 2001-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1249.5 µg/L 96% of the EPA limit 1300 µg/L
worst single sample: 1380 µg/L | 10/10 | SYR4 | 2014–2017 |
| TTHM | 17.82 µg/L 22% of the EPA limit 80 µg/L
worst single sample: 20 µg/L | 5/5 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 3/3 | LCR | 2025 |
| Lead | 4.324 µg/L 29% of the EPA limit 15 µg/L
worst single sample: 4.33 µg/L | 3/10 | SYR4 | 2014–2017 |
| Bromodichloromethane | 6.295 µg/L No EPA limit set
worst single sample: 6.5 µg/L | 2/2 | SYR4 | 2016–2019 |
| Chloroform | 4.515 µg/L No EPA limit set
worst single sample: 4.7 µg/L | 2/2 | SYR4 | 2016–2019 |
| Dibromochloromethane | 6.43 µg/L No EPA limit set
worst single sample: 6.6 µg/L | 2/2 | SYR4 | 2016–2019 |
| Fluoride | 129 µg/L 3.2% of the EPA limit 4000 µg/L
worst single sample: 130 µg/L | 2/6 | SYR4 | 2014–2017 |
| Bromoform | 2.1 µg/L No EPA limit set | 1/2 | SYR4 | 2016–2019 |
| Dibromoacetic Acid | 2.1 µg/L No EPA limit set | 1/2 | SYR4 | 2016–2019 |
| Dichloroacetic Acid | 2.8 µg/L No EPA limit set | 1/2 | SYR4 | 2016–2019 |
| Gross Beta Particle Activity | 6.7 pCi/L No EPA limit set | 1/4 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 6.7 µg/L 11% of the EPA limit 60 µg/L | 1/5 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 1.8 µg/L No EPA limit set | 1/2 | SYR4 | 2016–2019 |
64 contaminants tested, none detected
Utility contact
Frequently asked questions about Willow Hill S/D
Is Willow Hill S/D tap water safe to drink?
EPA monitoring detected 14 contaminants in Willow Hill S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Willow Hill S/D's water?
EPA monitoring detected Copper, TTHM, Lead, Lead, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Willow Hill S/D serve?
Willow Hill S/D reports serving 329 people in North Carolina, per its EPA record.
Has Willow Hill S/D had any water quality violations?
The EPA has 19 violations on file for Willow Hill S/D, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.