← North Carolina

Tap water quality report

Greymoss S/D

EPA monitoring tested this supplier for 78 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
16
detected
361
people served
5
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Durham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
33
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2002-07-01
Other Monitoring Resolved 2002-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1690 µg/L 130%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 2440 µg/L
41/43 SYR4 2013–2019
TTHM
16.65 µg/L 21%
of the EPA limit 80 µg/L
worst single sample: 17 µg/L
8/8 SYR4 2013–2019
Bromodichloromethane
4.6 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
6/6 SYR4 2014–2019
Combined Radium (-226 And -228)
4 pCi/L 80%
of the EPA limit 5 pCi/L
worst single sample: 4.2 pCi/L
6/9 SYR4 2013–2019
Dibromochloromethane
5.975 µg/L
No EPA limit set
worst single sample: 6 µg/L
6/6 SYR4 2014–2019
Chloroform
2.68 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
5/6 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2026
Bromoform
1.955 µg/L
No EPA limit set
worst single sample: 2 µg/L
4/6 SYR4 2014–2019
Lead
5.712 µg/L 38%
of the EPA limit 15 µg/L
worst single sample: 5.91 µg/L
4/43 SYR4 2013–2019
Fluoride
223 µg/L 5.6%
of the EPA limit 4000 µg/L
worst single sample: 230 µg/L
3/8 SYR4 2014–2017
Trichloroacetic Acid
1.2 µg/L
No EPA limit set
2/6 SYR4 2014–2019
Barium
579 µg/L 29%
of the EPA limit 2000 µg/L
1/8 SYR4 2014–2017
Dibromoacetic Acid
2.7 µg/L
No EPA limit set
1/6 SYR4 2014–2019
Dichloroacetic Acid
2.2 µg/L
No EPA limit set
1/6 SYR4 2014–2019
Heptachlor Epoxide
0.0220 µg/L 11%
of the EPA limit 0.2000 µg/L
1/13 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.1 µg/L 10%
of the EPA limit 60 µg/L
1/9 SYR4 2013–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHeptachlorHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLIRON, BRENT
Phone
919-653-6999
Email
bmilliron@aquaamerica.com

Frequently asked questions about Greymoss S/D

Is Greymoss S/D tap water safe to drink?

EPA monitoring detected 16 contaminants in Greymoss S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greymoss S/D's water?

EPA monitoring detected Copper, TTHM, Bromodichloromethane, Combined Radium (-226 And -228), Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Greymoss S/D serve?

Greymoss S/D reports serving 361 people in North Carolina, per its EPA record.

Has Greymoss S/D had any water quality violations?

The EPA has 33 violations on file for Greymoss S/D, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.