Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2019-10-01 → 2019-12-31 |
| MCL | Health-based | Resolved | 2019-10-01 → 2019-12-31 |
| MCL | Health-based | Resolved | 2019-10-01 → 2019-12-31 |
| MCL | Health-based | Resolved | 2019-10-01 → 2019-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 2180 µg/L 22% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 7.8 pCi/L 156% of the EPA limit, in the worst sample — 5 pCi/L | 14/14 | SYR4 | 2013–2019 |
| Lead | 8.9191 µg/L 59% of the EPA limit 15 µg/L | 5/20 | SYR4 | 2013–2018 |
| Copper | 14 µg/L 1.1% of the EPA limit 1300 µg/L | 2/15 | SYR4 | 2013–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 2/2 | LCR | 2022 |
| Chloroform | 0.5600 µg/L No EPA limit set | 1/4 | SYR4 | 2014–2019 |
| Combined Uranium | 2.533 µg/L 8.4% of the EPA limit 30 µg/L | 1/3 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 1.01 µg/L No EPA limit set | 1/4 | SYR4 | 2014–2019 |
| Nitrate-Nitrite | 2180 µg/L 22% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2019 |
| TTHM | 0.5600 µg/L 0.7% of the EPA limit 80 µg/L | 1/5 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 1.01 µg/L 1.7% of the EPA limit 60 µg/L | 1/5 | SYR4 | 2013–2019 |
66 contaminants tested, none detected
Utility contact
Frequently asked questions about Raintree Mhp
Is Raintree Mhp tap water safe to drink?
EPA monitoring detected 11 contaminants in Raintree Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Raintree Mhp's water?
EPA monitoring detected Nitrate, Combined Radium (-226 And -228), Lead, Copper, Lead, and others. The full list with the level and data source for each is above.
How many people does Raintree Mhp serve?
Raintree Mhp reports serving 85 people in North Carolina, per its EPA record.
Has Raintree Mhp had any water quality violations?
The EPA has 294 violations on file for Raintree Mhp, of which 34 are health-based (a contaminant limit or required treatment was breached) and 10 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.