← North Carolina

Tap water quality report

Goldston`S Mhp

EPA monitoring tested this supplier for 78 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
5
detected
43
people served
34
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Randolph

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

34
health-based violations
268
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01
TT Health-based Resolved 2004-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
24/24 LCR 2025
Nitrate
3700 µg/L 37%
of the EPA limit 10000 µg/L
12/16 SYR4 2012–2019
Copper
25 µg/L 1.9%
of the EPA limit 1300 µg/L
5/25 SYR4 2012–2018
Nitrate-Nitrite
3700 µg/L 37%
of the EPA limit 10000 µg/L
4/4 SYR4 2012–2019
Nitrite
2700 µg/L 270%
of the EPA limit, in the worst sample — 1000 µg/L
1/4 SYR4 2012–2019
73 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MONTERO, TONY
Phone
336-433-7225
Email
cardinalwaterinc@gmail.com

Frequently asked questions about Goldston`S Mhp

Is Goldston`S Mhp tap water safe to drink?

EPA monitoring detected 5 contaminants in Goldston`S Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Goldston`S Mhp's water?

EPA monitoring detected Lead, Nitrate, Copper, Nitrate-Nitrite, Nitrite. The full list with the level and data source for each is above.

How many people does Goldston`S Mhp serve?

Goldston`S Mhp reports serving 43 people in North Carolina, per its EPA record.

Has Goldston`S Mhp had any water quality violations?

The EPA has 268 violations on file for Goldston`S Mhp, of which 34 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.