← Montana

Tap water quality report

Greenacres County Water and Sewer Dist

EPA monitoring tested this supplier for 68 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
10
detected
450
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Flathead

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2020-06-01 → 2020-06-30
MON Monitoring Resolved 2020-06-01 → 2020-06-30
MON Monitoring Resolved 2020-06-01 → 2020-06-30
MR Monitoring Resolved 2006-07-01 → 2006-09-30
MR Monitoring Resolved 2006-07-01 → 2006-09-30
MR Monitoring Resolved 2006-07-01 → 2006-09-30
MR Monitoring Resolved 1993-07-01
MR Monitoring Resolved 1993-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
720 µg/L 7.2%
of the EPA limit 10000 µg/L
24/24 SYR4 2012–2019
Copper
120 µg/L 9.2%
of the EPA limit 1300 µg/L
12/15 SYR4 2013–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Combined Uranium
6 µg/L 20%
of the EPA limit 30 µg/L
6/6 SYR4 2014–2019
Lead
5 µg/L 33%
of the EPA limit 15 µg/L
4/15 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
5 pCi/L 33%
of the EPA limit 15 pCi/L
3/6 SYR4 2014–2019
Barium
180 µg/L 9%
of the EPA limit 2000 µg/L
2/2 SYR4 2012–2013
Combined Radium (-226 And -228)
2 pCi/L 40%
of the EPA limit 5 pCi/L
2/6 SYR4 2014–2019
Fluoride
140 µg/L 3.5%
of the EPA limit 4000 µg/L
2/2 SYR4 2012–2013
Nitrate
450 µg/L 4.5%
of the EPA limit 10000 µg/L
2/2 SYR4 2012
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DOMINICK, DEBORAH
Phone
406-212-9277

Frequently asked questions about Greenacres County Water and Sewer Dist

Is Greenacres County Water and Sewer Dist tap water safe to drink?

EPA monitoring detected 10 contaminants in Greenacres County Water and Sewer Dist's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenacres County Water and Sewer Dist's water?

EPA monitoring detected Nitrate-Nitrite, Copper, Lead, Combined Uranium, Lead, and others. The full list with the level and data source for each is above.

How many people does Greenacres County Water and Sewer Dist serve?

Greenacres County Water and Sewer Dist reports serving 450 people in Montana, per its EPA record.

Has Greenacres County Water and Sewer Dist had any water quality violations?

The EPA has 8 violations on file for Greenacres County Water and Sewer Dist, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.