← Montana

Tap water quality report

Greenwood Trailer Court

EPA monitoring tested this supplier for 64 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

64
contaminants tested
8
detected
53
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Missoula

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
301
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2022-09-27
TT Health-based Resolved 2022-09-27
TT Health-based Resolved 2022-09-27
MCL Health-based Resolved 1994-03-01 → 1994-03-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
690 µg/L 6.9%
of the EPA limit 10000 µg/L
32/32 SYR4 2012–2019
Copper
78 µg/L 6%
of the EPA limit 1300 µg/L
15/15 SYR4 2012–2018
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
12/12 LCR 2024
Lead
3 µg/L 20%
of the EPA limit 15 µg/L
4/15 SYR4 2012–2018
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
2/5 SYR4 2013–2017
Barium
300 µg/L 15%
of the EPA limit 2000 µg/L
1/1 SYR4 2013
Combined Radium (-226 And -228)
0.5000 pCi/L 10%
of the EPA limit 5 pCi/L
1/1 SYR4 2013
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
1/1 SYR4 2013
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PLUM PROPERTY MANAGEMENT
Phone
406-541-7586
Email
jenniferstockplum@gmail.com

Frequently asked questions about Greenwood Trailer Court

Is Greenwood Trailer Court tap water safe to drink?

EPA monitoring detected 8 contaminants in Greenwood Trailer Court's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenwood Trailer Court's water?

EPA monitoring detected Nitrate-Nitrite, Copper, Lead, Lead, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Greenwood Trailer Court serve?

Greenwood Trailer Court reports serving 53 people in Montana, per its EPA record.

Has Greenwood Trailer Court had any water quality violations?

The EPA has 301 violations on file for Greenwood Trailer Court, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.