← Missouri

Tap water quality report

Chapel Hill Subd

EPA monitoring tested this supplier for 69 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
10
detected
32
people served
43
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Cedar

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

43
health-based violations
57
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2007-09-01 → 2007-09-30
MCL Health-based Resolved 2007-09-01 → 2007-09-30
MCL Health-based Resolved 2007-09-01 → 2007-09-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1994-09-01 → 1994-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
25/25 LCR 2024
Copper
65.26 µg/L 5%
of the EPA limit 1300 µg/L
worst single sample: 66.7 µg/L
17/18 SYR4 2012–2019
Lead
1.932 µg/L 13%
of the EPA limit 15 µg/L
worst single sample: 1.98 µg/L
4/18 SYR4 2012–2019
Barium
73.18 µg/L 3.7%
of the EPA limit 2000 µg/L
worst single sample: 73.3 µg/L
3/3 SYR4 2013–2019
Fluoride
230 µg/L 5.8%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2019
Bromodichloromethane
0.5870 µg/L
No EPA limit set
worst single sample: 0.5900 µg/L
2/6 SYR4 2013–2019
Chloroform
0.9495 µg/L
No EPA limit set
worst single sample: 0.9700 µg/L
2/6 SYR4 2013–2019
Chromium
2.4025 µg/L 2.4%
of the EPA limit 100 µg/L
worst single sample: 2.42 µg/L
2/3 SYR4 2013–2019
Nitrate-Nitrite
23 µg/L 0.2%
of the EPA limit 10000 µg/L
2/16 SYR4 2012–2019
Combined Radium (-226 And -228)
1.2 pCi/L 24%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ARTHUR, ELLEN
Email
corgy2@gmail.com

Frequently asked questions about Chapel Hill Subd

Is Chapel Hill Subd tap water safe to drink?

EPA monitoring detected 10 contaminants in Chapel Hill Subd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Chapel Hill Subd's water?

EPA monitoring detected Lead, Copper, Lead, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Chapel Hill Subd serve?

Chapel Hill Subd reports serving 32 people in Missouri, per its EPA record.

Has Chapel Hill Subd had any water quality violations?

The EPA has 57 violations on file for Chapel Hill Subd, of which 43 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.