Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| RPT | Monitoring | Resolved | 2025-07-02 |
| MR | Monitoring | Resolved | 2014-10-01 |
| MR | Monitoring | Resolved | 2011-10-01 |
| Other | Monitoring | Resolved | 2010-07-01 |
| MR | Monitoring | Resolved | 2010-01-01 → 2010-12-31 |
| MR | Monitoring | Resolved | 2010-01-01 → 2010-12-31 |
| MR | Monitoring | Resolved | 2010-01-01 → 2010-12-31 |
| MR | Monitoring | Resolved | 2008-10-01 |
| MR | Monitoring | Archived | 1995-11-01 → 1995-11-30 |
| MR | Monitoring | Resolved | 1995-01-01 → 1995-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 12/12 | LCR | 2023 |
| Bromodichloromethane | 1.655 µg/L No EPA limit set
worst single sample: 1.7 µg/L | 2/2 | SYR4 | 2014–2015 |
| Chloroform | 8.5175 µg/L No EPA limit set
worst single sample: 8.9 µg/L | 2/2 | SYR4 | 2014–2015 |
| Fluoride | 895 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 900 µg/L | 2/2 | SYR4 | 2014–2017 |
| TTHM | 11.375 µg/L 14% of the EPA limit 80 µg/L
worst single sample: 11.4 µg/L | 2/2 | SYR4 | 2014–2017 |
| Total Haloacetic Acids (HAA5) | 2.4555 µg/L 4.1% of the EPA limit 60 µg/L
worst single sample: 2.48 µg/L | 2/2 | SYR4 | 2014–2017 |
| Combined Radium (-226 And -228) | 1.3 pCi/L 26% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2017 |
| Dibromoacetic Acid | 1.06 µg/L No EPA limit set | 1/1 | SYR4 | 2014 |
| Dibromochloromethane | 0.8000 µg/L No EPA limit set | 1/2 | SYR4 | 2014–2015 |
| Dichloroacetic Acid | 1.42 µg/L No EPA limit set | 1/1 | SYR4 | 2014 |
| Gross Alpha, Excl. Radon And U | 3.7 pCi/L 25% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2017 |
61 contaminants tested, none detected
Utility contact
Frequently asked questions about Red Hill Water Company, Inc.
Is Red Hill Water Company, Inc. tap water safe to drink?
EPA monitoring detected 11 contaminants in Red Hill Water Company, Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Red Hill Water Company, Inc.'s water?
EPA monitoring detected Lead, Bromodichloromethane, Chloroform, Fluoride, TTHM, and others. The full list with the level and data source for each is above.
How many people does Red Hill Water Company, Inc. serve?
Red Hill Water Company, Inc. reports serving 200 people in Maryland, per its EPA record.
Has Red Hill Water Company, Inc. had any water quality violations?
The EPA has 18 violations on file for Red Hill Water Company, Inc., of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.