← Maryland

Tap water quality report

Pine Hill Water Company

EPA monitoring tested this supplier for 72 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

72
contaminants tested
11
detected
140
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Charles

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
11
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2025-07-02
MR Monitoring Resolved 2014-10-01
MR Monitoring Resolved 2011-10-01
Other Monitoring Resolved 2010-07-01
MR Monitoring Resolved 2008-10-01
MR Monitoring Resolved 2005-09-01 → 2005-09-30
MR Monitoring Resolved 2005-09-01 → 2005-09-30
MR Monitoring Resolved 2005-09-01 → 2005-09-30
MR Monitoring Resolved 1994-04-01 → 1994-04-30
MR Monitoring Resolved 1994-04-01 → 1994-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0026 mg/L 17%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Fluoride
199 µg/L 5%
of the EPA limit 4000 µg/L
worst single sample: 200 µg/L
3/3 SYR4 2014–2017
Chloroform
1.9375 µg/L
No EPA limit set
worst single sample: 2 µg/L
2/2 SYR4 2014–2016
TTHM
2.761 µg/L 3.5%
of the EPA limit 80 µg/L
worst single sample: 2.8 µg/L
2/2 SYR4 2014–2017
Barium
220 µg/L 11%
of the EPA limit 2000 µg/L
1/3 SYR4 2014–2017
Bromodichloromethane
0.8000 µg/L
No EPA limit set
1/2 SYR4 2014–2016
Combined Radium (-226 And -228)
0.6000 pCi/L 12%
of the EPA limit 5 pCi/L
1/1 SYR4 2014
Ethylbenzene
1.91 µg/L 0.3%
of the EPA limit 700 µg/L
1/1 SYR4 2016
Gross Alpha, Excl. Radon And U
3.2 pCi/L 21%
of the EPA limit 15 pCi/L
1/1 SYR4 2014
Gross Beta Particle Activity
14.2 pCi/L
No EPA limit set
1/1 SYR4 2014
Xylenes, Total
11.97 µg/L 0.1%
of the EPA limit 10000 µg/L
1/1 SYR4 2016
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CROOKS, EDWARD
Phone
410-353-0383
Email
ecc989@hotmail.com

Frequently asked questions about Pine Hill Water Company

Is Pine Hill Water Company tap water safe to drink?

EPA monitoring detected 11 contaminants in Pine Hill Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pine Hill Water Company's water?

EPA monitoring detected Lead, Fluoride, Chloroform, TTHM, Barium, and others. The full list with the level and data source for each is above.

How many people does Pine Hill Water Company serve?

Pine Hill Water Company reports serving 140 people in Maryland, per its EPA record.

Has Pine Hill Water Company had any water quality violations?

The EPA has 11 violations on file for Pine Hill Water Company, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.