Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2007-07-01 → 2007-07-31 |
| MCL | Health-based | Archived | 2007-07-01 → 2007-07-31 |
| MCL | Health-based | Archived | 2007-07-01 → 2007-07-31 |
| Other | Monitoring | Resolved | 2004-07-01 |
| Other | Monitoring | Resolved | 2004-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1466 µg/L 113% of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 1680 µg/L | 189/192 | SYR4 | 2013–2019 |
| Lead | 16.65 µg/L 111% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 36 µg/L | 128/192 | SYR4 | 2013–2019 |
| Lead | 0.00072 mg/L 4.8% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Bromodichloromethane | 5.88 µg/L No EPA limit set
worst single sample: 7.2 µg/L | 13/16 | SYR4 | 2012–2019 |
| TTHM | 19.58 µg/L 24% of the EPA limit 80 µg/L
worst single sample: 23 µg/L | 13/16 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 9.62 µg/L 16% of the EPA limit 60 µg/L
worst single sample: 11.6 µg/L | 13/16 | SYR4 | 2012–2019 |
| Dibromochloromethane | 5.845 µg/L No EPA limit set
worst single sample: 7 µg/L | 12/16 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 4.71 µg/L No EPA limit set
worst single sample: 5.7 µg/L | 12/16 | SYR4 | 2012–2019 |
| Chloroform | 5.65 µg/L No EPA limit set
worst single sample: 6.1 µg/L | 11/16 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2 µg/L No EPA limit set
worst single sample: 2.2 µg/L | 9/16 | SYR4 | 2012–2019 |
| Bromoform | 2.84 µg/L No EPA limit set
worst single sample: 3 µg/L | 5/16 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 1.42 µg/L No EPA limit set
worst single sample: 1.5 µg/L | 5/16 | SYR4 | 2012–2019 |
| Barium | 177 µg/L 8.9% of the EPA limit 2000 µg/L
worst single sample: 180 µg/L | 2/4 | SYR4 | 2014–2017 |
| Combined Radium (-226 And -228) | 1.2305 pCi/L 25% of the EPA limit 5 pCi/L
worst single sample: 1.24 pCi/L | 2/2 | SYR4 | 2017 |
| Fluoride | 262.5 µg/L 6.6% of the EPA limit 4000 µg/L
worst single sample: 270 µg/L | 2/3 | SYR4 | 2014–2017 |
| Monobromoacetic Acid | 0.6375 µg/L No EPA limit set
worst single sample: 0.6400 µg/L | 2/16 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 1.5655 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 2/16 | SYR4 | 2012–2019 |
| Arsenic | 3 µg/L 30% of the EPA limit 10 µg/L | 1/4 | SYR4 | 2014–2017 |
| Beryllium, Total | 6 µg/L 150% of the EPA limit, at the 95th percentile of samples — 4 µg/L | 1/3 | SYR4 | 2014–2017 |
| Di(2-ethylhexyl) Phthalate | 0.5200 µg/L 8.7% of the EPA limit 6 µg/L | 1/4 | SYR4 | 2014–2017 |
| Gross Beta Particle Activity | 3.05 pCi/L No EPA limit set | 1/4 | SYR4 | 2014–2017 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about Fort Polk North Housing Water
Is Fort Polk North Housing Water tap water safe to drink?
EPA monitoring detected 21 contaminants in Fort Polk North Housing Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Fort Polk North Housing Water's water?
EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.
How many people does Fort Polk North Housing Water serve?
Fort Polk North Housing Water reports serving 2,155 people in Louisiana, per its EPA record.
Has Fort Polk North Housing Water had any water quality violations?
The EPA has 5 violations on file for Fort Polk North Housing Water, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.