← Louisiana

Tap water quality report

Village of Downsville Water

EPA monitoring tested this supplier for 82 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
22
detected
216
people served
387
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Union Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

387
health-based violations
582
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-04-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
41.225 µg/L
No EPA limit set
worst single sample: 45.5 µg/L
46/46 SYR4 2012–2019
Chloroform
94.65 µg/L
No EPA limit set
worst single sample: 112 µg/L
46/46 SYR4 2012–2019
Dibromochloromethane
31.1 µg/L
No EPA limit set
worst single sample: 103 µg/L
46/46 SYR4 2012–2019
TTHM
139.275 µg/L 174%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 267 µg/L
46/46 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
100.625 µg/L 168%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 113.7 µg/L
46/46 SYR4 2012–2019
Trichloroacetic Acid
39.16 µg/L
No EPA limit set
worst single sample: 50 µg/L
45/46 SYR4 2012–2019
Dichloroacetic Acid
55.66 µg/L
No EPA limit set
worst single sample: 70.3 µg/L
43/46 SYR4 2012–2019
Dibromoacetic Acid
9.625 µg/L
No EPA limit set
worst single sample: 11.9 µg/L
40/46 SYR4 2012–2019
Bromoform
8.419 µg/L
No EPA limit set
worst single sample: 142 µg/L
27/46 SYR4 2012–2019
Monochloroacetic Acid
3.3 µg/L
No EPA limit set
15/46 SYR4 2012–2019
Copper
500 µg/L 38%
of the EPA limit 1300 µg/L
14/21 SYR4 2012–2019
Lead
2.35 µg/L 16%
of the EPA limit 15 µg/L
worst single sample: 3 µg/L
14/21 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Fluoride
432 µg/L 11%
of the EPA limit 4000 µg/L
worst single sample: 440 µg/L
5/5 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
2.477 µg/L 41%
of the EPA limit 6 µg/L
worst single sample: 2.72 µg/L
4/5 SYR4 2013–2019
Monobromoacetic Acid
0.9640 µg/L
No EPA limit set
worst single sample: 1 µg/L
4/46 SYR4 2012–2019
Nitrate-Nitrite
44 µg/L 0.4%
of the EPA limit 10000 µg/L
4/22 SYR4 2012–2019
Barium
5.39 µg/L 0.3%
of the EPA limit 2000 µg/L
worst single sample: 5.4 µg/L
2/5 SYR4 2013–2019
Combined Radium (-226 And -228)
0.8516 pCi/L 17%
of the EPA limit 5 pCi/L
worst single sample: 0.8860 pCi/L
2/3 SYR4 2016–2019
Chromium
10 µg/L 10%
of the EPA limit 100 µg/L
1/5 SYR4 2013–2019
Gross Beta Particle Activity
1.44 pCi/L
No EPA limit set
1/5 SYR4 2013–2019
Hexachlorobenzene
0.2100 µg/L 21%
of the EPA limit 1 µg/L
1/5 SYR4 2013–2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SKAINS, REGGIE
Phone
318-548-8299
Email
reggieskains@bellsouth.net

Frequently asked questions about Village of Downsville Water

Is Village of Downsville Water tap water safe to drink?

EPA monitoring detected 22 contaminants in Village of Downsville Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Village of Downsville Water's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Village of Downsville Water serve?

Village of Downsville Water reports serving 216 people in Louisiana, per its EPA record.

Has Village of Downsville Water had any water quality violations?

The EPA has 582 violations on file for Village of Downsville Water, of which 387 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.