← Louisiana

Tap water quality report

Bayou Teche Water Works

EPA monitoring tested this supplier for 110 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
26
detected
10,137
people served
79
health-based violations
Water source
Ground water
Ownership
Private
Counties served
St. Martin Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

79
health-based violations
108
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2022-02-07
TT Health-based Resolved 2022-02-07
TT Health-based Resolved 2022-02-07
TT Health-based Resolved 2022-02-07
TT Health-based Unaddressed 2022-02-07
TT Health-based Unaddressed 2022-02-07
TT Health-based Unaddressed 2022-02-07
TT Health-based Resolved 2022-02-07
TT Health-based Resolved 2022-02-07

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
34.57 µg/L
No EPA limit set
50/50 SYR4 2012–2019
Chloroform
103.09 µg/L
No EPA limit set
50/50 SYR4 2012–2019
Dichloroacetic Acid
37.7 µg/L
No EPA limit set
50/50 SYR4 2012–2019
TTHM
144.39 µg/L 180%
of the EPA limit, in the worst sample — 80 µg/L
50/50 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
115.3 µg/L 192%
of the EPA limit, in the worst sample — 60 µg/L
50/50 SYR4 2012–2019
Trichloroacetic Acid
87 µg/L
No EPA limit set
49/50 SYR4 2012–2019
Dibromoacetic Acid
2.9 µg/L
No EPA limit set
45/50 SYR4 2012–2019
Copper
1700 µg/L 131%
of the EPA limit, in the worst sample — 1300 µg/L
43/67 SYR4 2013–2019
Dibromochloromethane
7.2 µg/L
No EPA limit set
39/50 SYR4 2012–2019
Lead
27 µg/L 180%
of the EPA limit, in the worst sample — 15 µg/L
36/67 SYR4 2013–2019
Arsenic
18 µg/L 180%
of the EPA limit, in the worst sample — 10 µg/L
29/31 SYR4 2013–2019
Barium
1200 µg/L 60%
of the EPA limit 2000 µg/L
28/32 SYR4 2013–2019
Monochloroacetic Acid
34 µg/L
No EPA limit set
19/50 SYR4 2012–2019
Gross Beta Particle Activity
6 pCi/L
No EPA limit set
13/16 SYR4 2013–2019
Fluoride
180 µg/L 4.5%
of the EPA limit 4000 µg/L
11/11 SYR4 2013–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
11/11 LCR 2025
Combined Radium (-226 And -228)
3.42 pCi/L 68%
of the EPA limit 5 pCi/L
9/13 SYR4 2016–2019
Monobromoacetic Acid
1.4 µg/L
No EPA limit set
9/50 SYR4 2012–2019
Nitrate-Nitrite
91 µg/L 0.9%
of the EPA limit 10000 µg/L
8/38 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
6.45 µg/L 108%
of the EPA limit, in the worst sample — 6 µg/L
7/13 SYR4 2013–2019
Benzo(A)Pyrene
0.0230 µg/L 12%
of the EPA limit 0.2000 µg/L
3/13 SYR4 2013–2019
Bromoform
1.33 µg/L
No EPA limit set
3/50 SYR4 2012–2019
Lithium
17 µg/L
No EPA limit set
2/2 UCMR-5 2023
Chromium
9.5 µg/L 9.5%
of the EPA limit 100 µg/L
1/11 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
3 pCi/L 20%
of the EPA limit 15 pCi/L
1/10 SYR4 2013–2017
P-Dichlorobenzene
3.8 µg/L 5.1%
of the EPA limit 75 µg/L
1/12 SYR4 2013–2019
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BERTRAND JR., MELVIN
Phone
337-319-6237
Email
MEL@BROUSSARDLA.COM

Frequently asked questions about Bayou Teche Water Works

Is Bayou Teche Water Works tap water safe to drink?

EPA monitoring detected 26 contaminants in Bayou Teche Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bayou Teche Water Works's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Bayou Teche Water Works serve?

Bayou Teche Water Works reports serving 10,137 people in Louisiana, per its EPA record.

Has Bayou Teche Water Works had any water quality violations?

The EPA has 108 violations on file for Bayou Teche Water Works, of which 79 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.