Tap water quality report

Savoy Swords Water System Inc

EPA monitoring tested this supplier for 110 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
25
detected
7,326
people served
12
health-based violations
Water source
Ground water
Ownership
Private
Counties served
St. Landry Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
22
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
TT Health-based Resolved 2025-04-01
MCL Health-based Resolved 2008-08-01 → 2008-08-31
MCL Health-based Resolved 2008-08-01 → 2008-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
12 µg/L 80%
of the EPA limit 15 µg/L
33/51 SYR4 2014–2019
Copper
1200 µg/L 92%
of the EPA limit 1300 µg/L
31/51 SYR4 2014–2019
Nitrate-Nitrite
1000 µg/L 10%
of the EPA limit 10000 µg/L
28/66 SYR4 2012–2019
Chloroform
24.8 µg/L
No EPA limit set
14/14 SYR4 2013–2019
Fluoride
960 µg/L 24%
of the EPA limit 4000 µg/L
14/14 SYR4 2012–2019
TTHM
66.5 µg/L 83%
of the EPA limit 80 µg/L
14/14 SYR4 2013–2019
Dibromoacetic Acid
8.2 µg/L
No EPA limit set
12/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
33.3 µg/L 55%
of the EPA limit 60 µg/L
12/14 SYR4 2013–2019
Bromodichloromethane
21.8 µg/L
No EPA limit set
11/14 SYR4 2013–2019
Dibromochloromethane
21.8 µg/L
No EPA limit set
11/14 SYR4 2013–2019
Dichloroacetic Acid
7.6 µg/L
No EPA limit set
11/14 SYR4 2013–2019
Trichloroacetic Acid
9.7 µg/L
No EPA limit set
11/14 SYR4 2013–2019
Bromoform
8.9 µg/L
No EPA limit set
10/14 SYR4 2013–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
9/9 LCR 2023
Barium
1000 µg/L 50%
of the EPA limit 2000 µg/L
8/15 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
23.54 µg/L 392%
of the EPA limit, in the worst sample — 6 µg/L
8/16 SYR4 2012–2019
Gross Beta Particle Activity
4 pCi/L
No EPA limit set
5/11 SYR4 2012–2019
Monochloroacetic Acid
11.8 µg/L
No EPA limit set
5/14 SYR4 2013–2019
Combined Radium (-226 And -228)
1.6 pCi/L 32%
of the EPA limit 5 pCi/L
4/7 SYR4 2015–2019
Lithium
23.3 µg/L
No EPA limit set
4/4 UCMR-5 2025
Monobromoacetic Acid
9.8 µg/L
No EPA limit set
2/14 SYR4 2013–2019
Selenium
0.7700 µg/L 1.5%
of the EPA limit 50 µg/L
2/15 SYR4 2012–2019
P-Dichlorobenzene
0.3100 µg/L 0.4%
of the EPA limit 75 µg/L
2/13 SYR4 2012–2019
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/15 SYR4 2012–2019
Cadmium
0.9800 µg/L 20%
of the EPA limit 5 µg/L
1/15 SYR4 2012–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SOILEAU, BRIAN
Phone
337-546-6812
Email
kathygaspardssws@rcsaccess.net

Frequently asked questions about Savoy Swords Water System Inc

Is Savoy Swords Water System Inc tap water safe to drink?

EPA monitoring detected 25 contaminants in Savoy Swords Water System Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Savoy Swords Water System Inc's water?

EPA monitoring detected Lead, Copper, Nitrate-Nitrite, Chloroform, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Savoy Swords Water System Inc serve?

Savoy Swords Water System Inc reports serving 7,326 people in Louisiana, per its EPA record.

Has Savoy Swords Water System Inc had any water quality violations?

The EPA has 22 violations on file for Savoy Swords Water System Inc, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.