← Louisiana

Tap water quality report

South Monroe Ws Gowc

EPA monitoring tested this supplier for 111 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
19
detected
7,335
people served
273
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Ouachita Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

273
health-based violations
280
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-07-01 → 2022-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Dibromoacetic Acid
23.2 µg/L
No EPA limit set
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
30.8 µg/L 51%
of the EPA limit 60 µg/L
57/57 SYR4 2012–2019
TTHM
222.4 µg/L 278%
of the EPA limit, in the worst sample — 80 µg/L
56/56 SYR4 2012–2019
Bromoform
181 µg/L
No EPA limit set
54/56 SYR4 2012–2019
Dibromochloromethane
34.8 µg/L
No EPA limit set
53/56 SYR4 2012–2019
Chloroform
38 µg/L
No EPA limit set
48/56 SYR4 2012–2019
Bromodichloromethane
8.25 µg/L
No EPA limit set
47/56 SYR4 2012–2019
Lead
37 µg/L 247%
of the EPA limit, in the worst sample — 15 µg/L
42/45 SYR4 2014–2018
Copper
600 µg/L 46%
of the EPA limit 1300 µg/L
41/45 SYR4 2014–2018
Monobromoacetic Acid
7.57 µg/L
No EPA limit set
24/57 SYR4 2012–2019
Trichloroacetic Acid
2.2 µg/L
No EPA limit set
22/57 SYR4 2012–2019
Dichloroacetic Acid
2.6 µg/L
No EPA limit set
18/57 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Barium
15 µg/L 0.8%
of the EPA limit 2000 µg/L
5/8 SYR4 2012–2018
Fluoride
400 µg/L 10%
of the EPA limit 4000 µg/L
5/8 SYR4 2012–2018
Monochloroacetic Acid
2.3 µg/L
No EPA limit set
5/57 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
1.9 µg/L 32%
of the EPA limit 6 µg/L
3/8 SYR4 2012–2018
Lithium
11.7 µg/L
No EPA limit set
2/2 UCMR-5 2025
Arsenic
0.5000 µg/L 5%
of the EPA limit 10 µg/L
1/8 SYR4 2012–2018
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitrate-NitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCQUEEN, PHILIP E.
Phone
318-322-3741
Email
PhilipM@northlouisianalawyers.com

Frequently asked questions about South Monroe Ws Gowc

Is South Monroe Ws Gowc tap water safe to drink?

EPA monitoring detected 19 contaminants in South Monroe Ws Gowc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in South Monroe Ws Gowc's water?

EPA monitoring detected Dibromoacetic Acid, Total Haloacetic Acids (HAA5), TTHM, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does South Monroe Ws Gowc serve?

South Monroe Ws Gowc reports serving 7,335 people in Louisiana, per its EPA record.

Has South Monroe Ws Gowc had any water quality violations?

The EPA has 280 violations on file for South Monroe Ws Gowc, of which 273 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.