Tap water quality report

Village of Goldonna Water

EPA monitoring tested this supplier for 82 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
23
detected
540
people served
10
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Natchitoches Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
25
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2021-02-11
TT Health-based Resolved 2021-02-11
TT Health-based Resolved 2021-02-11
TT Health-based Resolved 2021-02-11
TT Health-based Resolved 2013-11-01
TT Health-based Resolved 2013-11-01
TT Health-based Resolved 2012-12-02
TT Health-based Resolved 2012-12-02
TT Health-based Resolved 2012-12-02
TT Health-based Resolved 2012-12-02

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
6.15 µg/L 41%
of the EPA limit 15 µg/L
worst single sample: 13 µg/L
38/56 SYR4 2012–2019
Copper
1400 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 3800 µg/L
35/56 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
19/19 LCR 2026
Nitrate-Nitrite
1000 µg/L 10%
of the EPA limit 10000 µg/L
8/46 SYR4 2012–2019
TTHM
9.595 µg/L 12%
of the EPA limit 80 µg/L
worst single sample: 10.4 µg/L
8/19 SYR4 2012–2019
Dibromochloromethane
4 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
7/19 SYR4 2012–2019
Barium
67 µg/L 3.4%
of the EPA limit 2000 µg/L
6/9 SYR4 2013–2019
Bromodichloromethane
2.38 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
5/19 SYR4 2012–2019
Dibromoacetic Acid
1.56 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
5/19 SYR4 2012–2019
Fluoride
108 µg/L 2.7%
of the EPA limit 4000 µg/L
worst single sample: 110 µg/L
5/9 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
2.48 µg/L 4.1%
of the EPA limit 60 µg/L
worst single sample: 2.5 µg/L
5/19 SYR4 2012–2019
Bromoform
2.525 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
4/19 SYR4 2012–2019
Chloroform
0.9330 µg/L
No EPA limit set
worst single sample: 0.9600 µg/L
4/19 SYR4 2012–2019
Dichloroacetic Acid
0.7140 µg/L
No EPA limit set
worst single sample: 0.7200 µg/L
4/19 SYR4 2012–2019
Combined Radium (-226 And -228)
0.7309 pCi/L 15%
of the EPA limit 5 pCi/L
worst single sample: 0.7460 pCi/L
3/6 SYR4 2016–2019
Di(2-ethylhexyl) Phthalate
7.935 µg/L 132%
of the EPA limit, at the 95th percentile of samples — 6 µg/L
worst single sample: 8.74 µg/L
3/11 SYR4 2013–2019
Trichloroacetic Acid
0.5380 µg/L
No EPA limit set
worst single sample: 0.5500 µg/L
3/19 SYR4 2012–2019
Hexachlorobenzene
0.2365 µg/L 24%
of the EPA limit 1 µg/L
worst single sample: 0.2400 µg/L
2/9 SYR4 2013–2019
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/9 SYR4 2013–2019
Chromium
1.6 µg/L 1.6%
of the EPA limit 100 µg/L
1/9 SYR4 2013–2019
Gross Beta Particle Activity
2.93 pCi/L
No EPA limit set
1/9 SYR4 2013–2019
O-Dichlorobenzene
0.2500 µg/L 0%
of the EPA limit 600 µg/L
1/9 SYR4 2013–2019
P-Dichlorobenzene
0.3400 µg/L 0.5%
of the EPA limit 75 µg/L
1/9 SYR4 2013–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-Dichloroethylenetrans-1,2-Dichloroethylene

Utility contact

Contact
CLOUD, GAYLE
Phone
318-471-9559
Email
villageofgoldonna@gmail.com

Frequently asked questions about Village of Goldonna Water

Is Village of Goldonna Water tap water safe to drink?

EPA monitoring detected 23 contaminants in Village of Goldonna Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Village of Goldonna Water's water?

EPA monitoring detected Lead, Copper, Lead, Nitrate-Nitrite, TTHM, and others. The full list with the level and data source for each is above.

How many people does Village of Goldonna Water serve?

Village of Goldonna Water reports serving 540 people in Louisiana, per its EPA record.

Has Village of Goldonna Water had any water quality violations?

The EPA has 25 violations on file for Village of Goldonna Water, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.