← Louisiana

Tap water quality report

Rambin-Wallace Water

EPA monitoring tested this supplier for 82 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
21
detected
1,161
people served
15
health-based violations
Water source
Ground water
Ownership
Private
Counties served
De Soto Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

15
health-based violations
32
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Archived 2002-06-01 → 2002-06-30
MCL Health-based Archived 2002-06-01 → 2002-06-30
MCL Health-based Archived 1997-08-15 → 1997-09-14
MCL Health-based Archived 1997-08-15 → 1997-09-14
MCL Health-based Archived 1997-08-15 → 1997-09-14
MCL Health-based Archived 1997-08-15 → 1997-09-14

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
495 µg/L 38%
of the EPA limit 1300 µg/L
worst single sample: 700 µg/L
22/38 SYR4 2013–2019
Bromodichloromethane
7.67 µg/L
No EPA limit set
worst single sample: 7.8 µg/L
14/14 SYR4 2013–2019
Dibromochloromethane
10.805 µg/L
No EPA limit set
worst single sample: 11 µg/L
14/14 SYR4 2013–2019
Lead
3.35 µg/L 22%
of the EPA limit 15 µg/L
worst single sample: 4 µg/L
14/38 SYR4 2013–2019
TTHM
26.91 µg/L 34%
of the EPA limit 80 µg/L
worst single sample: 27.3 µg/L
14/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
16.335 µg/L 27%
of the EPA limit 60 µg/L
worst single sample: 17.7 µg/L
14/14 SYR4 2013–2019
Chloroform
3.96 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
13/14 SYR4 2013–2019
Bromoform
7.815 µg/L
No EPA limit set
worst single sample: 11.5 µg/L
12/14 SYR4 2013–2019
Dibromoacetic Acid
2.745 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
12/14 SYR4 2013–2019
Dichloroacetic Acid
3.15 µg/L
No EPA limit set
worst single sample: 3.7 µg/L
12/14 SYR4 2013–2019
Fluoride
278 µg/L 7%
of the EPA limit 4000 µg/L
worst single sample: 300 µg/L
12/12 SYR4 2013–2019
Barium
45.65 µg/L 2.3%
of the EPA limit 2000 µg/L
worst single sample: 46 µg/L
8/12 SYR4 2013–2019
Lead
0.0016 mg/L 11%
of the EPA limit 0.0150 mg/L
8/8 LCR 2025
Nitrate-Nitrite
47 µg/L 0.5%
of the EPA limit 10000 µg/L
8/38 SYR4 2012–2019
Trichloroacetic Acid
2.245 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
8/14 SYR4 2013–2019
Monochloroacetic Acid
13.75 µg/L
No EPA limit set
worst single sample: 14 µg/L
6/14 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
0.5480 µg/L 9.1%
of the EPA limit 6 µg/L
worst single sample: 0.5500 µg/L
3/8 SYR4 2013–2016
Hexachlorobenzene
0.3140 µg/L 31%
of the EPA limit 1 µg/L
worst single sample: 0.3400 µg/L
3/8 SYR4 2013–2016
Gross Alpha, Excl. Radon And U
5.9415 pCi/L 40%
of the EPA limit 15 pCi/L
worst single sample: 6.03 pCi/L
2/12 SYR4 2013–2019
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
1/12 SYR4 2013–2019
Gross Beta Particle Activity
5.81 pCi/L
No EPA limit set
1/12 SYR4 2013–2019
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HAIRE, BRUCE
Phone
318-663-1378
Email
rwws137@outlook.com

Frequently asked questions about Rambin-Wallace Water

Is Rambin-Wallace Water tap water safe to drink?

EPA monitoring detected 21 contaminants in Rambin-Wallace Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Rambin-Wallace Water's water?

EPA monitoring detected Copper, Bromodichloromethane, Dibromochloromethane, Lead, TTHM, and others. The full list with the level and data source for each is above.

How many people does Rambin-Wallace Water serve?

Rambin-Wallace Water reports serving 1,161 people in Louisiana, per its EPA record.

Has Rambin-Wallace Water had any water quality violations?

The EPA has 32 violations on file for Rambin-Wallace Water, of which 15 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.