← Louisiana

Tap water quality report

Vixen Water

EPA monitoring tested this supplier for 80 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
20
detected
750
people served
844
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Caldwell Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

844
health-based violations
1,098
violations on file
12
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
45.7 µg/L
No EPA limit set
38/38 SYR4 2013–2019
Chloroform
252 µg/L
No EPA limit set
38/38 SYR4 2013–2019
Dichloroacetic Acid
88.5 µg/L
No EPA limit set
38/38 SYR4 2013–2019
TTHM
303.7 µg/L 380%
of the EPA limit, in the worst sample — 80 µg/L
38/38 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
202 µg/L 337%
of the EPA limit, in the worst sample — 60 µg/L
38/38 SYR4 2013–2019
Trichloroacetic Acid
118 µg/L
No EPA limit set
37/38 SYR4 2013–2019
Dibromochloromethane
5.99 µg/L
No EPA limit set
36/38 SYR4 2013–2019
Dibromoacetic Acid
1.5 µg/L
No EPA limit set
20/38 SYR4 2013–2019
Monochloroacetic Acid
6.49 µg/L
No EPA limit set
16/38 SYR4 2013–2019
Lead
32 µg/L 213%
of the EPA limit, in the worst sample — 15 µg/L
13/19 SYR4 2012–2019
Copper
900 µg/L 69%
of the EPA limit 1300 µg/L
12/19 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Fluoride
1900 µg/L 48%
of the EPA limit 4000 µg/L
6/6 SYR4 2013–2019
Barium
17 µg/L 0.9%
of the EPA limit 2000 µg/L
4/6 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
2.4 µg/L 40%
of the EPA limit 6 µg/L
4/6 SYR4 2013–2019
Nitrate-Nitrite
39 µg/L 0.4%
of the EPA limit 10000 µg/L
4/28 SYR4 2012–2019
Combined Radium (-226 And -228)
0.8460 pCi/L 17%
of the EPA limit 5 pCi/L
2/4 SYR4 2016–2019
Monobromoacetic Acid
8 µg/L
No EPA limit set
2/38 SYR4 2013–2019
Cadmium
0.9100 µg/L 18%
of the EPA limit 5 µg/L
1/6 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
4.17 pCi/L 28%
of the EPA limit 15 pCi/L
1/4 SYR4 2013–2016
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCCORMICK, HOYT
Phone
318-435-5999
Email
vixenws@gmail.com

Frequently asked questions about Vixen Water

Is Vixen Water tap water safe to drink?

EPA monitoring detected 20 contaminants in Vixen Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Vixen Water's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Vixen Water serve?

Vixen Water reports serving 750 people in Louisiana, per its EPA record.

Has Vixen Water had any water quality violations?

The EPA has 1098 violations on file for Vixen Water, of which 844 are health-based (a contaminant limit or required treatment was breached) and 12 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.