← Louisiana

Tap water quality report

Calcasieu Parish Ww 12 Ward 3

EPA monitoring tested this supplier for 80 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
18
detected
2,130
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Calcasieu Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
4
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2016-04-01 → 2016-06-30
MR Monitoring Resolved 2016-04-01 → 2016-06-30
MR Monitoring Resolved 2016-04-01 → 2016-06-30
MR Monitoring Resolved 2016-04-01 → 2016-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
706 µg/L 54%
of the EPA limit 1300 µg/L
worst single sample: 1200 µg/L
43/52 SYR4 2015–2018
Lead
13.82 µg/L 92%
of the EPA limit 15 µg/L
worst single sample: 61 µg/L
25/52 SYR4 2015–2018
Bromoform
11.79 µg/L
No EPA limit set
worst single sample: 14.1 µg/L
12/12 SYR4 2014–2019
Chloroform
4.745 µg/L
No EPA limit set
worst single sample: 4.8 µg/L
12/12 SYR4 2014–2019
Dibromoacetic Acid
4.77 µg/L
No EPA limit set
worst single sample: 5.1 µg/L
12/12 SYR4 2014–2019
Dibromochloromethane
14.24 µg/L
No EPA limit set
worst single sample: 14.9 µg/L
12/12 SYR4 2014–2019
TTHM
35.905 µg/L 45%
of the EPA limit 80 µg/L
worst single sample: 39.7 µg/L
12/12 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
9.69 µg/L 16%
of the EPA limit 60 µg/L
worst single sample: 9.8 µg/L
12/12 SYR4 2014–2019
Bromodichloromethane
8.35 µg/L
No EPA limit set
worst single sample: 8.8 µg/L
11/12 SYR4 2014–2019
Dichloroacetic Acid
3.31 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
10/12 SYR4 2014–2019
Trichloroacetic Acid
1.63 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
8/12 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2024
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
4/4 SYR4 2014–2017
Monochloroacetic Acid
4.87 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
4/12 SYR4 2014–2019
Di(2-ethylhexyl) Phthalate
0.8075 µg/L 13%
of the EPA limit 6 µg/L
worst single sample: 0.8100 µg/L
2/4 SYR4 2014–2017
Monobromoacetic Acid
0.8310 µg/L
No EPA limit set
worst single sample: 0.8400 µg/L
2/12 SYR4 2014–2019
Combined Radium (-226 And -228)
0.7690 pCi/L 15%
of the EPA limit 5 pCi/L
1/2 SYR4 2017
Gross Beta Particle Activity
1.95 pCi/L
No EPA limit set
1/4 SYR4 2014–2017
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrate-NitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FRELOT, TERRY
Phone
337-721-3700
Email
tfrelot@calcasieu.gov

Frequently asked questions about Calcasieu Parish Ww 12 Ward 3

Is Calcasieu Parish Ww 12 Ward 3 tap water safe to drink?

EPA monitoring detected 18 contaminants in Calcasieu Parish Ww 12 Ward 3's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Calcasieu Parish Ww 12 Ward 3's water?

EPA monitoring detected Copper, Lead, Bromoform, Chloroform, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Calcasieu Parish Ww 12 Ward 3 serve?

Calcasieu Parish Ww 12 Ward 3 reports serving 2,130 people in Louisiana, per its EPA record.

Has Calcasieu Parish Ww 12 Ward 3 had any water quality violations?

The EPA has 4 violations on file for Calcasieu Parish Ww 12 Ward 3, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.