← Louisiana

Tap water quality report

Town of Plain Dealing Water

EPA monitoring tested this supplier for 84 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

84
contaminants tested
23
detected
2,346
people served
330
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Bossier Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

330
health-based violations
480
violations on file
6
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2026-01-25
TT Health-based Unaddressed 2026-01-25
TT Health-based Unaddressed 2026-01-25
TT Health-based Unaddressed 2026-01-25
TT Health-based Unaddressed 2026-01-25
TT Health-based Unaddressed 2026-01-25
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromoform
340 µg/L
No EPA limit set
53/53 SYR4 2012–2019
TTHM
403.7 µg/L 505%
of the EPA limit, in the worst sample — 80 µg/L
53/53 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
187.4 µg/L 312%
of the EPA limit, in the worst sample — 60 µg/L
53/53 SYR4 2012–2019
Dibromoacetic Acid
82.9 µg/L
No EPA limit set
52/53 SYR4 2012–2019
Chloroform
5.7 µg/L
No EPA limit set
51/53 SYR4 2012–2019
Dibromochloromethane
69.1 µg/L
No EPA limit set
51/53 SYR4 2012–2019
Bromodichloromethane
15 µg/L
No EPA limit set
49/53 SYR4 2012–2019
Fluoride
3300 µg/L 83%
of the EPA limit 4000 µg/L
44/44 SYR4 2013–2019
Trichloroacetic Acid
7.6 µg/L
No EPA limit set
43/53 SYR4 2012–2019
Monobromoacetic Acid
7.9 µg/L
No EPA limit set
38/53 SYR4 2012–2019
Dichloroacetic Acid
34.5 µg/L
No EPA limit set
37/53 SYR4 2012–2019
Lead
60 µg/L 400%
of the EPA limit, in the worst sample — 15 µg/L
19/40 SYR4 2014–2019
Copper
1100 µg/L 85%
of the EPA limit 1300 µg/L
14/29 SYR4 2014–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
11/11 LCR 2023
Arsenic
3 µg/L 30%
of the EPA limit 10 µg/L
9/12 SYR4 2013–2019
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
9/12 SYR4 2013–2019
Monochloroacetic Acid
135 µg/L
No EPA limit set
7/53 SYR4 2012–2019
Nitrate-Nitrite
68 µg/L 0.7%
of the EPA limit 10000 µg/L
6/30 SYR4 2012–2019
Combined Radium (-226 And -228)
2.31 pCi/L 46%
of the EPA limit 5 pCi/L
5/7 SYR4 2016–2019
Gross Beta Particle Activity
3.99 pCi/L
No EPA limit set
4/9 SYR4 2013–2019
Nitrate
47 µg/L 0.5%
of the EPA limit 10000 µg/L
2/8 SYR4 2017
Cyanide
3.1 µg/L 1.6%
of the EPA limit 200 µg/L
1/10 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
1.11 µg/L 19%
of the EPA limit 6 µg/L
1/10 SYR4 2013–2019
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
COOK, JAMES
Email
mayor@plaindealingla.org

Frequently asked questions about Town of Plain Dealing Water

Is Town of Plain Dealing Water tap water safe to drink?

EPA monitoring detected 23 contaminants in Town of Plain Dealing Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Town of Plain Dealing Water's water?

EPA monitoring detected Bromoform, TTHM, Total Haloacetic Acids (HAA5), Dibromoacetic Acid, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Town of Plain Dealing Water serve?

Town of Plain Dealing Water reports serving 2,346 people in Louisiana, per its EPA record.

Has Town of Plain Dealing Water had any water quality violations?

The EPA has 480 violations on file for Town of Plain Dealing Water, of which 330 are health-based (a contaminant limit or required treatment was breached) and 6 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.