← Louisiana

Tap water quality report

Edwards Millcreek Water

EPA monitoring tested this supplier for 14 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
11
detected
114
people served
22
health-based violations
Water source
GWP
Ownership
Private
Counties served
Bienville Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

22
health-based violations
208
violations on file
11
still open
ViolationTypeStatusPeriod
TT Health-based Addressed 2024-10-17
MCL Health-based Archived 2016-04-01 → 2016-04-30
MCL Health-based Archived 2016-04-01 → 2016-04-30
MCL Health-based Archived 2016-04-01 → 2016-04-30
MCL Health-based Archived 2016-04-01 → 2016-04-30
MCL Health-based Resolved 2013-01-01 → 2013-01-31
MCL Health-based Resolved 2013-01-01 → 2013-01-31
MCL Health-based Resolved 2013-01-01 → 2013-01-31
MCL Health-based Resolved 2013-01-01 → 2013-01-31
MCL Health-based Resolved 2013-01-01 → 2013-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
6.4 µg/L 43%
of the EPA limit 15 µg/L
worst single sample: 7 µg/L
13/16 SYR4 2012–2019
Copper
100 µg/L 7.7%
of the EPA limit 1300 µg/L
7/16 SYR4 2012–2019
Chloroform
6.84 µg/L
No EPA limit set
worst single sample: 7.8 µg/L
7/8 SYR4 2013–2019
TTHM
10.351 µg/L 13%
of the EPA limit 80 µg/L
worst single sample: 12.4 µg/L
7/8 SYR4 2013–2019
Bromodichloromethane
3.025 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
6/8 SYR4 2013–2019
Dibromochloromethane
1.245 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
6/8 SYR4 2013–2019
Dichloroacetic Acid
3.375 µg/L
No EPA limit set
worst single sample: 3.6 µg/L
6/8 SYR4 2013–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
6/6 LCR 2022
Total Haloacetic Acids (HAA5)
6.175 µg/L 10%
of the EPA limit 60 µg/L
worst single sample: 6.5 µg/L
6/8 SYR4 2013–2019
Trichloroacetic Acid
2.675 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
6/8 SYR4 2013–2019
Dibromoacetic Acid
0.7040 µg/L
No EPA limit set
worst single sample: 0.7100 µg/L
4/8 SYR4 2013–2019
3 contaminants tested, none detected
BromoformMonobromoacetic AcidMonochloroacetic Acid

Utility contact

Contact
REED, VANESSA
Phone
318-497-9009
Email
ministerbraggs@gmail.com

Frequently asked questions about Edwards Millcreek Water

Is Edwards Millcreek Water tap water safe to drink?

EPA monitoring detected 11 contaminants in Edwards Millcreek Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Edwards Millcreek Water's water?

EPA monitoring detected Lead, Copper, Chloroform, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Edwards Millcreek Water serve?

Edwards Millcreek Water reports serving 114 people in Louisiana, per its EPA record.

Has Edwards Millcreek Water had any water quality violations?

The EPA has 208 violations on file for Edwards Millcreek Water, of which 22 are health-based (a contaminant limit or required treatment was breached) and 11 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.