← Kansas

Tap water quality report

Butler Co Rwd 1

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
782
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Butler

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
80
violations on file
0
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2025-08-01 → 2025-08-31
MON Monitoring Resolved 2025-08-01 → 2025-08-31
MON Monitoring Resolved 2025-08-01 → 2025-08-31
MR Monitoring Resolved 2025-08-01 → 2025-08-31
MR Monitoring Resolved 2025-08-01 → 2025-08-31
MR Monitoring Resolved 2025-08-01 → 2025-08-31
RPT Monitoring Resolved 2024-12-01
RPT Monitoring Resolved 2024-12-01
RPT Monitoring Resolved 2024-12-01
MON Monitoring Resolved 2024-10-01 → 2024-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
190 µg/L 15%
of the EPA limit 1300 µg/L
30/30 SYR4 2012–2018
Bromodichloromethane
21 µg/L
No EPA limit set
20/20 SYR4 2013–2019
Chloroform
78 µg/L
No EPA limit set
20/20 SYR4 2013–2019
Dibromochloromethane
4.5 µg/L
No EPA limit set
20/20 SYR4 2013–2019
Dichloroacetic Acid
52 µg/L
No EPA limit set
20/20 SYR4 2013–2019
TTHM
100 µg/L 125%
of the EPA limit, in the worst sample — 80 µg/L
20/20 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
140 µg/L 233%
of the EPA limit, in the worst sample — 60 µg/L
20/20 SYR4 2013–2019
Trichloroacetic Acid
85 µg/L
No EPA limit set
20/20 SYR4 2013–2019
Lead
9.7 µg/L 65%
of the EPA limit 15 µg/L
19/30 SYR4 2012–2018
Dibromoacetic Acid
2.9 µg/L
No EPA limit set
17/20 SYR4 2013–2019
Monochloroacetic Acid
5.3 µg/L
No EPA limit set
15/20 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2024
Monobromoacetic Acid
1.3 µg/L
No EPA limit set
6/20 SYR4 2013–2019
1 contaminants tested, none detected
Bromoform

Utility contact

Contact
FAIR, BROOKE
Phone
316-364-1132
Email
burwd1@yahoo.com

Frequently asked questions about Butler Co Rwd 1

Is Butler Co Rwd 1 tap water safe to drink?

EPA monitoring detected 13 contaminants in Butler Co Rwd 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Butler Co Rwd 1's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Butler Co Rwd 1 serve?

Butler Co Rwd 1 reports serving 782 people in Kansas, per its EPA record.

Has Butler Co Rwd 1 had any water quality violations?

The EPA has 80 violations on file for Butler Co Rwd 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.