← Kansas

Tap water quality report

Barton County Community College

EPA monitoring tested this supplier for 51 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

51
contaminants tested
20
detected
1,000
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Barton

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
6
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2002-12-01 → 2002-12-31
MR Monitoring Resolved 2002-12-01 → 2002-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1400 µg/L 14%
of the EPA limit 10000 µg/L
worst single sample: 3100 µg/L
44/44 SYR4 2012–2019
Copper
242.5 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 280 µg/L
36/36 SYR4 2012–2018
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
12/12 LCR 2024
Bromoform
22.8 µg/L
No EPA limit set
worst single sample: 27 µg/L
7/7 SYR4 2013–2019
Dibromoacetic Acid
7.97 µg/L
No EPA limit set
worst single sample: 9.2 µg/L
7/7 SYR4 2013–2019
Dibromochloromethane
9.42 µg/L
No EPA limit set
worst single sample: 9.6 µg/L
7/7 SYR4 2013–2019
TTHM
34.4 µg/L 43%
of the EPA limit 80 µg/L
worst single sample: 38 µg/L
7/7 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
10.43 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 11 µg/L
7/7 SYR4 2013–2019
Barium
89.75 µg/L 4.5%
of the EPA limit 2000 µg/L
worst single sample: 90 µg/L
6/6 SYR4 2012–2018
Bromodichloromethane
2.775 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
6/7 SYR4 2013–2019
Fluoride
462.5 µg/L 12%
of the EPA limit 4000 µg/L
worst single sample: 490 µg/L
6/6 SYR4 2012–2018
Monobromoacetic Acid
2.075 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
6/7 SYR4 2013–2019
Selenium
6.275 µg/L 13%
of the EPA limit 50 µg/L
worst single sample: 6.3 µg/L
6/6 SYR4 2012–2018
Lead
2.5 µg/L 17%
of the EPA limit 15 µg/L
worst single sample: 2.6 µg/L
5/36 SYR4 2012–2018
Arsenic
5.07 µg/L 51%
of the EPA limit 10 µg/L
worst single sample: 5.1 µg/L
4/6 SYR4 2012–2018
Chromium
4.38 µg/L 4.4%
of the EPA limit 100 µg/L
worst single sample: 4.5 µg/L
4/6 SYR4 2012–2018
Dichloroacetic Acid
0.8010 µg/L
No EPA limit set
worst single sample: 0.8100 µg/L
4/7 SYR4 2013–2019
Combined Radium (-226 And -228)
1.185 pCi/L 24%
of the EPA limit 5 pCi/L
worst single sample: 1.2 pCi/L
2/2 SYR4 2014–2017
Chloroform
0.5700 µg/L
No EPA limit set
1/7 SYR4 2013–2019
Monochloroacetic Acid
2.7 µg/L
No EPA limit set
1/7 SYR4 2013–2019
31 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosAtrazineBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideDichloromethaneEthylene DibromideEthylbenzeneMercuryStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DEAN, MARK
Phone
620-792-9235
Email
DeanM@bartonccc.edu

Frequently asked questions about Barton County Community College

Is Barton County Community College tap water safe to drink?

EPA monitoring detected 20 contaminants in Barton County Community College's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Barton County Community College's water?

EPA monitoring detected Nitrate, Copper, Lead, Bromoform, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Barton County Community College serve?

Barton County Community College reports serving 1,000 people in Kansas, per its EPA record.

Has Barton County Community College had any water quality violations?

The EPA has 6 violations on file for Barton County Community College, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.