← Indiana

Tap water quality report

Osgood Water Department

EPA monitoring tested this supplier for 73 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

73
contaminants tested
18
detected
1,692
people served
4
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Ripley

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
40
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
RPT Monitoring Resolved 2016-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
93.5 µg/L 117%
of the EPA limit, in the worst sample — 80 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
88.3 µg/L 147%
of the EPA limit, in the worst sample — 60 µg/L
57/57 SYR4 2012–2019
Atrazine
0.5100 µg/L 17%
of the EPA limit 3 µg/L
18/32 SYR4 2012–2019
Nitrate
690 µg/L 6.9%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Copper
264 µg/L 20%
of the EPA limit 1300 µg/L
10/10 SYR4 2018
Fluoride
866 µg/L 22%
of the EPA limit 4000 µg/L
7/8 SYR4 2012–2019
Lead
0.0020 mg/L 14%
of the EPA limit 0.0150 mg/L
7/7 LCR 2024
Simazine
0.8300 µg/L 21%
of the EPA limit 4 µg/L
4/32 SYR4 2012–2019
Barium
199 µg/L 10%
of the EPA limit 2000 µg/L
3/8 SYR4 2012–2019
Bromodichloromethane
10.6 µg/L
No EPA limit set
3/3 SYR4 2012–2014
Chloroform
29 µg/L
No EPA limit set
3/3 SYR4 2012–2014
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
2/8 SYR4 2012–2019
Dibromochloromethane
1 µg/L
No EPA limit set
2/3 SYR4 2012–2014
Antimony, Total
0.5000 µg/L 8.3%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Arsenic
0.6000 µg/L 6%
of the EPA limit 10 µg/L
1/8 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
0.7600 pCi/L 5.1%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Methoxychlor
0.2800 µg/L 0.7%
of the EPA limit 40 µg/L
1/27 SYR4 2012–2018
Selenium
2.1 µg/L 4.2%
of the EPA limit 50 µg/L
1/8 SYR4 2012–2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryOxamylPentachlorophenolPicloramStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NEWHART, JOHN J
Phone
812-621-2959
Email
watersupt@osgoodindiana.org

Frequently asked questions about Osgood Water Department

Is Osgood Water Department tap water safe to drink?

EPA monitoring detected 18 contaminants in Osgood Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Osgood Water Department's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Atrazine, Nitrate, Copper, and others. The full list with the level and data source for each is above.

How many people does Osgood Water Department serve?

Osgood Water Department reports serving 1,692 people in Indiana, per its EPA record.

Has Osgood Water Department had any water quality violations?

The EPA has 40 violations on file for Osgood Water Department, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.