← Indiana

Tap water quality report

Gatewood Estates

EPA monitoring tested this supplier for 72 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

72
contaminants tested
9
detected
202
people served
3
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Marshall

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
1,171
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2017-01-22
TT Health-based Resolved 2017-01-22
TT Health-based Resolved 2017-01-22
MR Monitoring Resolved 2025-07-12
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
MR Monitoring Resolved 2024-01-01
MR Monitoring Resolved 2024-01-01
MR Monitoring Resolved 2022-01-01 → 2022-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
200 µg/L 2%
of the EPA limit 10000 µg/L
10/18 SYR4 2012–2019
Arsenic
3.4 µg/L 34%
of the EPA limit 10 µg/L
9/9 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2024
Copper
1 µg/L 0.1%
of the EPA limit 1300 µg/L
6/10 SYR4 2017–2018
Barium
89 µg/L 4.5%
of the EPA limit 2000 µg/L
3/3 SYR4 2012–2018
Fluoride
300 µg/L 7.5%
of the EPA limit 4000 µg/L
3/3 SYR4 2012–2018
Nitrate-Nitrite
200 µg/L 2%
of the EPA limit 10000 µg/L
2/3 SYR4 2012–2018
Chromium
1.5 µg/L 1.5%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
0.3870 pCi/L 2.6%
of the EPA limit 15 pCi/L
1/1 SYR4 2017
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GEE, DAVID
Phone
574-276-6828
Email
davidgee520@gmail.com

Frequently asked questions about Gatewood Estates

Is Gatewood Estates tap water safe to drink?

EPA monitoring detected 9 contaminants in Gatewood Estates's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gatewood Estates's water?

EPA monitoring detected Nitrate, Arsenic, Lead, Copper, Barium, and others. The full list with the level and data source for each is above.

How many people does Gatewood Estates serve?

Gatewood Estates reports serving 202 people in Indiana, per its EPA record.

Has Gatewood Estates had any water quality violations?

The EPA has 1171 violations on file for Gatewood Estates, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.