← Indiana

Tap water quality report

Plymouth Water Department

EPA monitoring tested this supplier for 104 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
15
detected
10,241
people served
2
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Marshall

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
116
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1995-06-01 → 1995-06-30
MCL Health-based Resolved 1995-06-01 → 1995-06-30
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
RPT Monitoring Resolved 2021-07-01
RPT Monitoring Resolved 2021-07-01
RPT Monitoring Resolved 2021-07-01
MR Monitoring Resolved 2018-04-01 → 2018-06-30
MR Monitoring Resolved 2018-04-01 → 2018-06-30
MR Monitoring Resolved 2018-04-01 → 2018-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
47.3 µg/L 59%
of the EPA limit 80 µg/L
86/86 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
21.7 µg/L 36%
of the EPA limit 60 µg/L
64/86 SYR4 2012–2019
Copper
260 µg/L 20%
of the EPA limit 1300 µg/L
30/30 SYR4 2017
Nitrate
700 µg/L 7%
of the EPA limit 10000 µg/L
18/36 SYR4 2012–2019
Lead
0.0027 mg/L 18%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Lead
3.7 µg/L 25%
of the EPA limit 15 µg/L
13/30 SYR4 2017
Barium
83 µg/L 4.2%
of the EPA limit 2000 µg/L
6/6 SYR4 2012–2018
Fluoride
1000 µg/L 25%
of the EPA limit 4000 µg/L
6/6 SYR4 2012–2018
Bromodichloromethane
4.7 µg/L
No EPA limit set
3/6 SYR4 2012–2018
Chloroform
13 µg/L
No EPA limit set
3/6 SYR4 2012–2018
Nitrate-Nitrite
400 µg/L 4%
of the EPA limit 10000 µg/L
3/6 SYR4 2012–2018
Arsenic
1.5 µg/L 15%
of the EPA limit 10 µg/L
1/6 SYR4 2012–2018
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/6 SYR4 2012–2018
Dibromochloromethane
1 µg/L
No EPA limit set
1/6 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
0.7200 pCi/L 4.8%
of the EPA limit 15 pCi/L
1/1 SYR4 2015
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
VOLLRATH, MICHAEL W.
Phone
574-936-2543
Email
water@plymouthin.com

Frequently asked questions about Plymouth Water Department

Is Plymouth Water Department tap water safe to drink?

EPA monitoring detected 15 contaminants in Plymouth Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Plymouth Water Department's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Plymouth Water Department serve?

Plymouth Water Department reports serving 10,241 people in Indiana, per its EPA record.

Has Plymouth Water Department had any water quality violations?

The EPA has 116 violations on file for Plymouth Water Department, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.