EPA monitoring tested this supplier for 77 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
18
detected
1,544
people served
0
health-based violations
Water source
SWP
Ownership
Federal government
Counties served
Williamson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
49
violations on file
8
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2025-07-12
Other Monitoring Unaddressed 2025-07-12
MR Monitoring Archived 2025-07-01 → 2025-09-30
MR Monitoring Archived 2025-07-01 → 2025-09-30
MR Monitoring Archived 2025-07-01 → 2025-09-30
MR Monitoring Archived 2025-07-01 → 2025-09-30
Other Monitoring Unaddressed 2025-07-01
Other Monitoring Unaddressed 2025-04-12
Other Monitoring Unaddressed 2025-04-12
MR Monitoring Archived 2025-04-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
21.3 µg/L
No EPA limit set
32/32 SYR4 2012–2019
Chloroform
51.5 µg/L
No EPA limit set
32/32 SYR4 2012–2019
Dibromochloromethane
14.1 µg/L
No EPA limit set
32/32 SYR4 2012–2019
Dichloroacetic Acid
22.8 µg/L
No EPA limit set
32/32 SYR4 2012–2019
TTHM
88.3 µg/L 110%
of the EPA limit, in the worst sample — 80 µg/L
32/32 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
34.5 µg/L 57%
of the EPA limit 60 µg/L
32/32 SYR4 2012–2019
Trichloroacetic Acid
7.8 µg/L
No EPA limit set
31/32 SYR4 2012–2019
Dibromoacetic Acid
3.8 µg/L
No EPA limit set
29/32 SYR4 2012–2019
Bromoform
5.4 µg/L
No EPA limit set
23/32 SYR4 2012–2019
Nitrate
457 µg/L 4.6%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Nitrate-Nitrite
457 µg/L 4.6%
of the EPA limit 10000 µg/L
8/8 SYR4 2012–2019
Monochloroacetic Acid
2.6 µg/L
No EPA limit set
4/32 SYR4 2012–2019
Xylenes, Total
0.9120 µg/L 0%
of the EPA limit 10000 µg/L
3/9 SYR4 2014–2019
Barium
16.4 µg/L 0.8%
of the EPA limit 2000 µg/L
2/2 SYR4 2014–2017
Fluoride
906 µg/L 23%
of the EPA limit 4000 µg/L
2/2 SYR4 2014–2017
Arsenic
0.6400 µg/L 6.4%
of the EPA limit 10 µg/L
1/2 SYR4 2014–2017
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
1/32 SYR4 2012–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MOTT, CHRISTOPHER W
Phone
618-964-1441
Email
C2MOTT@BOP.GOV

Frequently asked questions about Fci-Marion

Is Fci-Marion tap water safe to drink?

EPA monitoring detected 18 contaminants in Fci-Marion's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fci-Marion's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Fci-Marion serve?

Fci-Marion reports serving 1,544 people in Illinois, per its EPA record.

Has Fci-Marion had any water quality violations?

The EPA has 49 violations on file for Fci-Marion, of which 0 are health-based (a contaminant limit or required treatment was breached) and 8 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.