← Illinois

Tap water quality report

Grand Valley Village Mhp

EPA monitoring tested this supplier for 14 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
11
detected
912
people served
0
health-based violations
Water source
SWP
Ownership
Private
Counties served
Sangamon

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
39
violations on file
1
still open
ViolationTypeStatusPeriod
MON Monitoring Archived 2026-03-01 → 2026-03-31
MR Monitoring Archived 2026-03-01 → 2026-03-31
Other Monitoring Unaddressed 2025-07-01
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
25.75 µg/L 2%
of the EPA limit 1300 µg/L
worst single sample: 76 µg/L
26/40 SYR4 2019
Bromodichloromethane
10.655 µg/L
No EPA limit set
worst single sample: 10.7 µg/L
10/10 SYR4 2018–2019
Chloroform
55.625 µg/L
No EPA limit set
worst single sample: 56.3 µg/L
10/10 SYR4 2018–2019
Dibromochloromethane
3.257 µg/L
No EPA limit set
worst single sample: 3.32 µg/L
10/10 SYR4 2018–2019
Dichloroacetic Acid
23.055 µg/L
No EPA limit set
worst single sample: 23.1 µg/L
10/10 SYR4 2018–2019
TTHM
66.89 µg/L 84%
of the EPA limit 80 µg/L
worst single sample: 67.7 µg/L
10/10 SYR4 2018–2019
Total Haloacetic Acids (HAA5)
28.055 µg/L 47%
of the EPA limit 60 µg/L
worst single sample: 28.1 µg/L
10/10 SYR4 2018–2019
Trichloroacetic Acid
4.952 µg/L
No EPA limit set
worst single sample: 4.97 µg/L
10/10 SYR4 2018–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Monobromoacetic Acid
6.7225 µg/L
No EPA limit set
worst single sample: 7.55 µg/L
6/10 SYR4 2018–2019
Lead
53.06 µg/L 354%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 62 µg/L
4/40 SYR4 2019
3 contaminants tested, none detected
BromoformDibromoacetic AcidMonochloroacetic Acid

Utility contact

Contact
KOBISH, KIM
Phone
248-208-5614
Email
kkobish@mshapirorealestate.com

Frequently asked questions about Grand Valley Village Mhp

Is Grand Valley Village Mhp tap water safe to drink?

EPA monitoring detected 11 contaminants in Grand Valley Village Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Grand Valley Village Mhp's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Grand Valley Village Mhp serve?

Grand Valley Village Mhp reports serving 912 people in Illinois, per its EPA record.

Has Grand Valley Village Mhp had any water quality violations?

The EPA has 39 violations on file for Grand Valley Village Mhp, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.