Tap water quality report

Wildwood Subdivision - Lake Co Pw

EPA monitoring tested this supplier for 44 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
14
detected
14,832
people served
39
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Lake

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

39
health-based violations
45
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30
MCL Health-based Resolved 1989-10-01 → 1993-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
10.5 µg/L
No EPA limit set
67/67 SYR4 2012–2019
Chloroform
17.5 µg/L
No EPA limit set
67/67 SYR4 2012–2019
Dibromochloromethane
7.67 µg/L
No EPA limit set
67/67 SYR4 2012–2019
TTHM
37.3 µg/L 47%
of the EPA limit 80 µg/L
67/67 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
11.89 µg/L 20%
of the EPA limit 60 µg/L
64/67 SYR4 2012–2019
Dichloroacetic Acid
4.92 µg/L
No EPA limit set
60/67 SYR4 2012–2019
Bromoform
2.01 µg/L
No EPA limit set
51/67 SYR4 2012–2019
Trichloroacetic Acid
3.19 µg/L
No EPA limit set
43/67 SYR4 2012–2019
Monobromoacetic Acid
3.2 µg/L
No EPA limit set
42/67 SYR4 2012–2019
Copper
2727 µg/L 210%
of the EPA limit, in the worst sample — 1300 µg/L
39/60 SYR4 2014–2017
Lead
0.0013 mg/L 8.3%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Dibromoacetic Acid
1.59 µg/L
No EPA limit set
13/67 SYR4 2012–2019
Lead
91.3 µg/L 609%
of the EPA limit, in the worst sample — 15 µg/L
3/60 SYR4 2014–2017
Monochloroacetic Acid
2.82 µg/L
No EPA limit set
1/67 SYR4 2012–2019
30 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Frequently asked questions about Wildwood Subdivision - Lake Co Pw

Is Wildwood Subdivision - Lake Co Pw tap water safe to drink?

EPA monitoring detected 14 contaminants in Wildwood Subdivision - Lake Co Pw's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wildwood Subdivision - Lake Co Pw's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Wildwood Subdivision - Lake Co Pw serve?

Wildwood Subdivision - Lake Co Pw reports serving 14,832 people, per its EPA record.

Has Wildwood Subdivision - Lake Co Pw had any water quality violations?

The EPA has 45 violations on file for Wildwood Subdivision - Lake Co Pw, of which 39 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.