← Illinois

Tap water quality report

Grayslake

EPA monitoring tested this supplier for 44 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
13
detected
21,248
people served
13
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Lake

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

13
health-based violations
21
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2000-09-01 → 2000-09-30
MCL Health-based Archived 2000-09-01 → 2000-09-30
MCL Health-based Archived 1999-08-01 → 1999-08-31
MCL Health-based Archived 1999-08-01 → 1999-08-31
TT Health-based Resolved 1994-01-01
TT Health-based Resolved 1994-01-01
TT Health-based Resolved 1992-12-21
TT Health-based Resolved 1992-12-21
MCL Health-based Archived 1992-10-01 → 1992-10-31
MCL Health-based Archived 1992-10-01 → 1992-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
10.9 µg/L
No EPA limit set
67/67 SYR4 2012–2019
Chloroform
31.3 µg/L
No EPA limit set
67/67 SYR4 2012–2019
Dibromochloromethane
7.837 µg/L
No EPA limit set
67/67 SYR4 2012–2019
TTHM
50.3 µg/L 63%
of the EPA limit 80 µg/L
67/67 SYR4 2012–2019
Bromoform
3.626 µg/L
No EPA limit set
58/67 SYR4 2012–2019
Lead
24.7 µg/L 165%
of the EPA limit, in the worst sample — 15 µg/L
53/90 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
13.9 µg/L 23%
of the EPA limit 60 µg/L
52/67 SYR4 2012–2019
Dibromoacetic Acid
2.5 µg/L
No EPA limit set
35/67 SYR4 2012–2019
Copper
520 µg/L 40%
of the EPA limit 1300 µg/L
28/90 SYR4 2013–2019
Trichloroacetic Acid
6.89 µg/L
No EPA limit set
28/67 SYR4 2012–2019
Lead
0.0120 mg/L 80%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Dichloroacetic Acid
11.4 µg/L
No EPA limit set
16/67 SYR4 2012–2019
Monobromoacetic Acid
2.14 µg/L
No EPA limit set
6/67 SYR4 2012–2019
31 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
RIGGS, PETER A.
Phone
847-223-8515
Email
PRIGGS@VILLAGEOFGRAYSLAKE.COM

Frequently asked questions about Grayslake

Is Grayslake tap water safe to drink?

EPA monitoring detected 13 contaminants in Grayslake's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Grayslake's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Grayslake serve?

Grayslake reports serving 21,248 people in Illinois, per its EPA record.

Has Grayslake had any water quality violations?

The EPA has 21 violations on file for Grayslake, of which 13 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.