← Illinois

Tap water quality report

Greenfield

EPA monitoring tested this supplier for 78 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
20
detected
1,097
people served
164
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Greene

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

164
health-based violations
227
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
87.4 µg/L
No EPA limit set
60/60 SYR4 2012–2019
TTHM
98 µg/L 123%
of the EPA limit, in the worst sample — 80 µg/L
60/60 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
190 µg/L 317%
of the EPA limit, in the worst sample — 60 µg/L
59/60 SYR4 2012–2019
Trichloroacetic Acid
73.7 µg/L
No EPA limit set
59/60 SYR4 2012–2019
Dichloroacetic Acid
116 µg/L
No EPA limit set
58/60 SYR4 2012–2019
Bromodichloromethane
13.3 µg/L
No EPA limit set
57/60 SYR4 2012–2019
Dibromochloromethane
2.2 µg/L
No EPA limit set
44/60 SYR4 2012–2019
Copper
790 µg/L 61%
of the EPA limit 1300 µg/L
30/30 SYR4 2012–2018
Atrazine
4.3 µg/L 143%
of the EPA limit, in the worst sample — 3 µg/L
24/33 SYR4 2012–2019
Lead
0.0027 mg/L 18%
of the EPA limit 0.0150 mg/L
23/23 LCR 2025
Nitrate
1800 µg/L 18%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
48 µg/L 320%
of the EPA limit, in the worst sample — 15 µg/L
12/30 SYR4 2012–2018
Monochloroacetic Acid
6.97 µg/L
No EPA limit set
10/60 SYR4 2012–2019
Barium
56 µg/L 2.8%
of the EPA limit 2000 µg/L
8/8 SYR4 2012–2019
Fluoride
898 µg/L 22%
of the EPA limit 4000 µg/L
8/8 SYR4 2012–2019
Monobromoacetic Acid
13.4 µg/L
No EPA limit set
6/60 SYR4 2012–2019
Nitrate-Nitrite
1600 µg/L 16%
of the EPA limit 10000 µg/L
3/3 SYR4 2012–2018
Simazine
4.2 µg/L 105%
of the EPA limit, in the worst sample — 4 µg/L
3/22 SYR4 2012–2019
Arsenic
1.2 µg/L 12%
of the EPA limit 10 µg/L
2/8 SYR4 2012–2019
2,4-D
1.1 µg/L 1.6%
of the EPA limit 70 µg/L
1/10 SYR4 2012–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TPAntimony, TotalBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HUNT, DEBBIE
Phone
217-368-2332
Email
clerk@greenfieldillinois.org

Frequently asked questions about Greenfield

Is Greenfield tap water safe to drink?

EPA monitoring detected 20 contaminants in Greenfield's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenfield's water?

EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Greenfield serve?

Greenfield reports serving 1,097 people in Illinois, per its EPA record.

Has Greenfield had any water quality violations?

The EPA has 227 violations on file for Greenfield, of which 164 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.