← Illinois

Tap water quality report

South Chicago Heights

EPA monitoring tested this supplier for 44 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
10
detected
3,924
people served
5
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Cook

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
10
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1997-07-01 → 1997-07-31
TT Health-based Resolved 1993-02-04
TT Health-based Resolved 1993-02-04
MR Monitoring Unaddressed 2026-01-01
MR Monitoring Unaddressed 2026-01-01
Other Monitoring Resolved 2016-07-01
Other Monitoring Resolved 2016-07-01
MR Monitoring Archived 1977-06-30 → 1981-06-29

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
486.2 µg/L 37%
of the EPA limit 1300 µg/L
worst single sample: 852 µg/L
45/60 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
25/25 LCR 2026
Bromodichloromethane
8.68 µg/L
No EPA limit set
worst single sample: 9 µg/L
23/23 SYR4 2012–2019
Chloroform
10.53 µg/L
No EPA limit set
worst single sample: 11.7 µg/L
23/23 SYR4 2012–2019
Dibromochloromethane
4.9 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
23/23 SYR4 2012–2019
TTHM
23.35 µg/L 29%
of the EPA limit 80 µg/L
worst single sample: 24.3 µg/L
23/23 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.105 µg/L 10%
of the EPA limit 60 µg/L
worst single sample: 6.2 µg/L
20/23 SYR4 2012–2019
Trichloroacetic Acid
3.02 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
20/23 SYR4 2012–2019
Dichloroacetic Acid
3.5 µg/L
No EPA limit set
18/23 SYR4 2012–2019
Lead
10.181 µg/L 68%
of the EPA limit 15 µg/L
worst single sample: 10.4 µg/L
2/60 SYR4 2013–2019
34 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformDibromoacetic AcidHfpo-DaMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
MARTINEZ-GOMEZ, NORA
Phone
708-755-1880
Email
nmartinez@southchicagoheights.com

Frequently asked questions about South Chicago Heights

Is South Chicago Heights tap water safe to drink?

EPA monitoring detected 10 contaminants in South Chicago Heights's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in South Chicago Heights's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does South Chicago Heights serve?

South Chicago Heights reports serving 3,924 people in Illinois, per its EPA record.

Has South Chicago Heights had any water quality violations?

The EPA has 10 violations on file for South Chicago Heights, of which 5 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.