← Illinois

Tap water quality report

Xenia

EPA monitoring tested this supplier for 44 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
12
detected
542
people served
25
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Clay

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

25
health-based violations
60
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2004-02-01 → 2004-02-29
TT Health-based Resolved 2004-02-01 → 2004-02-29
TT Health-based Resolved 2004-02-01 → 2004-02-29
TT Health-based Resolved 2004-02-01 → 2004-02-29
TT Health-based Resolved 2004-02-01 → 2004-02-29
TT Health-based Resolved 2004-01-01 → 2004-01-31
TT Health-based Resolved 2004-01-01 → 2004-01-31
TT Health-based Resolved 2004-01-01 → 2004-01-31
TT Health-based Resolved 2004-01-01 → 2004-01-31
TT Health-based Resolved 2004-01-01 → 2004-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
18.3 µg/L
No EPA limit set
32/32 SYR4 2012–2019
Chloroform
53.6 µg/L
No EPA limit set
32/32 SYR4 2012–2019
Dichloroacetic Acid
28.9 µg/L
No EPA limit set
32/32 SYR4 2012–2019
TTHM
75 µg/L 94%
of the EPA limit 80 µg/L
32/32 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
48.8 µg/L 81%
of the EPA limit 60 µg/L
32/32 SYR4 2012–2019
Trichloroacetic Acid
19.9 µg/L
No EPA limit set
32/32 SYR4 2012–2019
Dibromochloromethane
3.1 µg/L
No EPA limit set
19/32 SYR4 2012–2019
Copper
1250 µg/L 96%
of the EPA limit 1300 µg/L
14/30 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Lead
66.7 µg/L 445%
of the EPA limit, in the worst sample — 15 µg/L
5/30 SYR4 2012–2018
Dibromoacetic Acid
1.4 µg/L
No EPA limit set
3/32 SYR4 2012–2019
Monochloroacetic Acid
2.6 µg/L
No EPA limit set
3/32 SYR4 2012–2019
32 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformHfpo-DaMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
GOLDEN, TINA
Phone
618-678-2271
Email
XENIAVIL@WABASH.NET

Frequently asked questions about Xenia

Is Xenia tap water safe to drink?

EPA monitoring detected 12 contaminants in Xenia's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Xenia's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Xenia serve?

Xenia reports serving 542 people in Illinois, per its EPA record.

Has Xenia had any water quality violations?

The EPA has 60 violations on file for Xenia, of which 25 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.