Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2018-09-21 |
| TT | Health-based | Resolved | 2018-09-21 |
| TT | Health-based | Resolved | 2018-09-21 |
| TT | Health-based | Resolved | 2018-09-21 |
| TT | Health-based | Resolved | 2018-09-21 |
| MCL | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| MCL | Health-based | Archived | 2007-09-01 → 2007-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 1980 µg/L 20% of the EPA limit 10000 µg/L | 14/16 | SYR4 | 2012–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2025 |
| Arsenic | 1 µg/L 10% of the EPA limit 10 µg/L | 1/1 | SYR4 | 2019 |
| Barium | 74 µg/L 3.7% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2019 |
| Combined Radium (-226 And -228) | 1 pCi/L 20% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2016 |
| Combined Uranium | 1.08 µg/L 3.6% of the EPA limit 30 µg/L | 1/2 | SYR4 | 2013–2019 |
| Fluoride | 400 µg/L 10% of the EPA limit 4000 µg/L | 1/1 | SYR4 | 2019 |
| Gross Alpha, Excl. Radon And U | 0.9700 pCi/L 6.5% of the EPA limit 15 pCi/L | 1/2 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 0.5700 pCi/L No EPA limit set | 1/1 | SYR4 | 2013 |
| Nitrate-Nitrite | 1840 µg/L 18% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2019 |
43 contaminants tested, none detected
Utility contact
Frequently asked questions about J and K Water Corp
Is J and K Water Corp tap water safe to drink?
EPA monitoring detected 10 contaminants in J and K Water Corp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in J and K Water Corp's water?
EPA monitoring detected Nitrate, Lead, Arsenic, Barium, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.
How many people does J and K Water Corp serve?
J and K Water Corp reports serving 370 people in Idaho, per its EPA record.
Has J and K Water Corp had any water quality violations?
The EPA has 196 violations on file for J and K Water Corp, of which 11 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.