← Idaho

Tap water quality report

Valley Hi Estates

EPA monitoring tested this supplier for 66 contaminants and detected 3. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

66
contaminants tested
3
detected
140
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Boise

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
35
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2006-10-01 → 2006-10-31
MCL Health-based Resolved 2001-07-01 → 2001-07-31
MCL Health-based Archived 2000-11-01 → 2000-11-30
MCL Health-based Archived 2000-09-01 → 2000-09-30
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1996-08-01 → 1996-08-31
MCL Health-based Archived 1992-12-01 → 1992-12-31
MON Monitoring Resolved 2019-10-01 → 2019-10-31
MON Monitoring Resolved 2019-10-01 → 2019-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0080 mg/L 53%
of the EPA limit 0.0150 mg/L
11/11 LCR 2024
Fluoride
1532 µg/L 38%
of the EPA limit 4000 µg/L
worst single sample: 1560 µg/L
3/3 SYR4 2013–2019
Barium
110 µg/L 5.5%
of the EPA limit 2000 µg/L
1/1 SYR4 2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DEULEN, GARY
Phone
208-586-1645
Email
gary.deulen@frontier.com

Frequently asked questions about Valley Hi Estates

Is Valley Hi Estates tap water safe to drink?

EPA monitoring detected 3 contaminants in Valley Hi Estates's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Valley Hi Estates's water?

EPA monitoring detected Lead, Fluoride, Barium. The full list with the level and data source for each is above.

How many people does Valley Hi Estates serve?

Valley Hi Estates reports serving 140 people in Idaho, per its EPA record.

Has Valley Hi Estates had any water quality violations?

The EPA has 35 violations on file for Valley Hi Estates, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.