← New York

Tap water quality report

Horse Creek Village

EPA monitoring tested this supplier for 69 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
13
detected
85
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Polk

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
29
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2026-03-01 → 2026-03-31
MON Monitoring Archived 2026-03-01 → 2026-03-31
MON Monitoring Resolved 2025-12-01 → 2025-12-31
MR Monitoring Resolved 2025-12-01 → 2025-12-31
MON Monitoring Resolved 2024-07-01 → 2024-07-31
MR Monitoring Resolved 2024-07-01 → 2024-07-31
MON Monitoring Resolved 2024-06-01 → 2024-06-30
MR Monitoring Resolved 2024-06-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MON Monitoring Resolved 2024-04-01 → 2024-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Nitrate
3900 µg/L 39%
of the EPA limit 10000 µg/L
10/20 SYR4 2012–2019
Fluoride
205 µg/L 5.1%
of the EPA limit 4000 µg/L
6/6 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
15.3 µg/L 26%
of the EPA limit 60 µg/L
4/4 SYR4 2012–2018
Barium
15 µg/L 0.8%
of the EPA limit 2000 µg/L
3/3 SYR4 2012–2018
Copper
7.6 µg/L 0.6%
of the EPA limit 1300 µg/L
3/3 SYR4 2012–2018
Nitrite
180 µg/L 18%
of the EPA limit 1000 µg/L
3/11 SYR4 2012–2019
TTHM
33.3 µg/L 42%
of the EPA limit 80 µg/L
3/4 SYR4 2012–2018
Chromium
2.6 µg/L 2.6%
of the EPA limit 100 µg/L
2/3 SYR4 2012–2018
Arsenic
3.9 µg/L 39%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2018
Cadmium
0.2000 µg/L 4%
of the EPA limit 5 µg/L
1/3 SYR4 2012–2018
Combined Uranium
1.9668 µg/L 6.6%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Selenium
0.9000 µg/L 1.8%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HEATHER HALLACK / THOMAS BOOKER
Phone
518-417-1550

Frequently asked questions about Horse Creek Village

Is Horse Creek Village tap water safe to drink?

EPA monitoring detected 13 contaminants in Horse Creek Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Horse Creek Village's water?

EPA monitoring detected Lead, Nitrate, Fluoride, Total Haloacetic Acids (HAA5), Barium, and others. The full list with the level and data source for each is above.

How many people does Horse Creek Village serve?

Horse Creek Village reports serving 85 people in New York, per its EPA record.

Has Horse Creek Village had any water quality violations?

The EPA has 29 violations on file for Horse Creek Village, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.