← Florida

Tap water quality report

City of Lake Wales/Park Water Company

EPA monitoring tested this supplier for 98 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
14
detected
1,948
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Polk

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
38
violations on file
2
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2025-06-01 → 2025-06-30
MON Monitoring Resolved 2025-06-01 → 2025-06-30
MR Monitoring Resolved 2025-06-01 → 2025-06-30
MR Monitoring Resolved 2025-06-01 → 2025-06-30
MR Monitoring Resolved 2024-05-01 → 2024-05-31
MON Monitoring Resolved 2024-05-01 → 2024-05-31
MR Monitoring Resolved 2023-08-01 → 2023-08-31
MON Monitoring Resolved 2023-08-01 → 2023-08-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31
MR Monitoring Unaddressed 2022-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0023 mg/L 15%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
TTHM
40.9 µg/L 51%
of the EPA limit 80 µg/L
12/12 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
18.71 µg/L 31%
of the EPA limit 60 µg/L
12/12 SYR4 2012–2019
Fluoride
350 µg/L 8.8%
of the EPA limit 4000 µg/L
6/6 SYR4 2012–2018
Nitrate
30 µg/L 0.3%
of the EPA limit 10000 µg/L
4/14 SYR4 2012–2018
Barium
39 µg/L 2%
of the EPA limit 2000 µg/L
3/3 SYR4 2012–2018
Copper
7 µg/L 0.5%
of the EPA limit 1300 µg/L
3/3 SYR4 2012–2018
Dalapon
0.3800 µg/L 0.2%
of the EPA limit 200 µg/L
2/3 SYR4 2012–2018
Arsenic
1.9 µg/L 19%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2018
Beryllium, Total
0.2000 µg/L 5%
of the EPA limit 4 µg/L
1/3 SYR4 2012–2018
Chromium
2.4 µg/L 2.4%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Lead
0.3000 µg/L 2%
of the EPA limit 15 µg/L
1/3 SYR4 2012–2018
Nitrite
30 µg/L 3%
of the EPA limit 1000 µg/L
1/7 SYR4 2012–2018
Selenium
1.8 µg/L 3.6%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SARAH KIRKLAND
Phone
863-678-4182

Frequently asked questions about City of Lake Wales/Park Water Company

Is City of Lake Wales/Park Water Company tap water safe to drink?

EPA monitoring detected 14 contaminants in City of Lake Wales/Park Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Lake Wales/Park Water Company's water?

EPA monitoring detected Lead, TTHM, Total Haloacetic Acids (HAA5), Fluoride, Nitrate, and others. The full list with the level and data source for each is above.

How many people does City of Lake Wales/Park Water Company serve?

City of Lake Wales/Park Water Company reports serving 1,948 people in Florida, per its EPA record.

Has City of Lake Wales/Park Water Company had any water quality violations?

The EPA has 38 violations on file for City of Lake Wales/Park Water Company, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.