EPA monitoring tested this supplier for 69 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
14
detected
40
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Hillsborough

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2004-01-01 → 2004-03-31
MCL Health-based Archived 1991-02-01 → 1991-02-28
Other Monitoring Resolved 2002-10-01
Other Monitoring Resolved 2002-10-01
MR Monitoring Archived 1993-10-01 → 1993-10-31
MR Monitoring Archived 1993-09-01 → 1993-09-30
MR Monitoring Archived 1992-07-01 → 1992-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Fluoride
1300 µg/L 33%
of the EPA limit 4000 µg/L
6/6 SYR4 2012–2018
TTHM
57.428 µg/L 72%
of the EPA limit 80 µg/L
worst single sample: 60.43 µg/L
5/5 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
28.1 µg/L 47%
of the EPA limit 60 µg/L
worst single sample: 30.9 µg/L
5/5 SYR4 2012–2018
Antimony, Total
0.4800 µg/L 8%
of the EPA limit 6 µg/L
worst single sample: 0.5000 µg/L
3/3 SYR4 2012–2018
Barium
64.4 µg/L 3.2%
of the EPA limit 2000 µg/L
worst single sample: 65 µg/L
3/3 SYR4 2012–2018
Arsenic
0.5900 µg/L 5.9%
of the EPA limit 10 µg/L
worst single sample: 0.6000 µg/L
2/3 SYR4 2012–2018
Copper
30.48 µg/L 2.3%
of the EPA limit 1300 µg/L
worst single sample: 32 µg/L
2/3 SYR4 2012–2018
Nitrate
88 µg/L 0.9%
of the EPA limit 10000 µg/L
2/16 SYR4 2012–2019
Cyanide
14 µg/L 7%
of the EPA limit 200 µg/L
1/3 SYR4 2012–2018
Cadmium
0.1000 µg/L 2%
of the EPA limit 5 µg/L
1/3 SYR4 2012–2018
Dichloromethane
0.4300 µg/L 8.6%
of the EPA limit 5 µg/L
1/3 SYR4 2012–2018
Lead
1 µg/L 6.7%
of the EPA limit 15 µg/L
1/3 SYR4 2012–2018
Selenium
0.8000 µg/L 1.6%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BRIAN SWEAT
Phone
813-417-0182

Frequently asked questions about Riverside Mhp

Is Riverside Mhp tap water safe to drink?

EPA monitoring detected 14 contaminants in Riverside Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Riverside Mhp's water?

EPA monitoring detected Lead, Fluoride, TTHM, Total Haloacetic Acids (HAA5), Antimony, Total, and others. The full list with the level and data source for each is above.

How many people does Riverside Mhp serve?

Riverside Mhp reports serving 40 people in Florida, per its EPA record.

Has Riverside Mhp had any water quality violations?

The EPA has 7 violations on file for Riverside Mhp, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.