← Florida

Tap water quality report

Hcwrd/Eastlake

EPA monitoring tested this supplier for 68 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
14
detected
2,074
people served
2
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Hillsborough

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-06-01 → 2014-06-30
MCL Health-based Resolved 2014-06-01 → 2014-06-30
MR Monitoring Resolved 2006-04-01 → 2006-04-30
MR Monitoring Resolved 2006-04-01 → 2006-04-30
MR Monitoring Resolved 2006-04-01 → 2006-04-30
Other Monitoring Resolved 2003-07-01
Other Monitoring Resolved 2003-07-01
Other Monitoring Resolved 2003-07-01
Other Monitoring Resolved 2003-07-01
MR Monitoring Archived 1993-06-01 → 1993-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
37.9 µg/L 47%
of the EPA limit 80 µg/L
36/38 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
18.252 µg/L 30%
of the EPA limit 60 µg/L
36/38 SYR4 2012–2019
Lead
0.0021 mg/L 14%
of the EPA limit 0.0150 mg/L
17/17 LCR 2024
Nitrate
580 µg/L 5.8%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2015
Fluoride
141 µg/L 3.5%
of the EPA limit 4000 µg/L
5/5 SYR4 2012–2015
Arsenic
6.8 µg/L 68%
of the EPA limit 10 µg/L
2/2 SYR4 2012–2015
Barium
9.5 µg/L 0.5%
of the EPA limit 2000 µg/L
2/2 SYR4 2012–2015
Copper
2.9 µg/L 0.2%
of the EPA limit 1300 µg/L
2/2 SYR4 2012–2015
Selenium
3.4 µg/L 6.8%
of the EPA limit 50 µg/L
2/2 SYR4 2012–2015
cis-1,2-Dichloroethylene
0.5700 µg/L 0.8%
of the EPA limit 70 µg/L
2/3 SYR4 2012–2016
Antimony, Total
1.6 µg/L 27%
of the EPA limit 6 µg/L
1/2 SYR4 2012–2015
Lead
0.1000 µg/L 0.7%
of the EPA limit 15 µg/L
1/2 SYR4 2012–2015
Nitrite
19 µg/L 1.9%
of the EPA limit 1000 µg/L
1/8 SYR4 2012–2015
Thallium, Total
0.1000 µg/L 5%
of the EPA limit 2 µg/L
1/2 SYR4 2012–2015
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, TotalO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LISA RHEA, PE
Phone
813-612-7761

Frequently asked questions about Hcwrd/Eastlake

Is Hcwrd/Eastlake tap water safe to drink?

EPA monitoring detected 14 contaminants in Hcwrd/Eastlake's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hcwrd/Eastlake's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Nitrate, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Hcwrd/Eastlake serve?

Hcwrd/Eastlake reports serving 2,074 people in Florida, per its EPA record.

Has Hcwrd/Eastlake had any water quality violations?

The EPA has 16 violations on file for Hcwrd/Eastlake, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.