Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MON | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MON | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MON | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MON | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2017-06-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2016-10-01 → 2016-10-31 |
| MR | Monitoring | Resolved | 2016-10-01 → 2016-10-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2024 |
| Nitrate | 4700 µg/L 47% of the EPA limit 10000 µg/L | 18/20 | SYR4 | 2012–2019 |
| Fluoride | 180 µg/L 4.5% of the EPA limit 4000 µg/L | 5/6 | SYR4 | 2012–2018 |
| TTHM | 10.0025 µg/L 13% of the EPA limit 80 µg/L
worst single sample: 11.48 µg/L | 4/5 | SYR4 | 2012–2018 |
| Barium | 5.16 µg/L 0.3% of the EPA limit 2000 µg/L
worst single sample: 5.2 µg/L | 3/3 | SYR4 | 2012–2018 |
| Copper | 1.09 µg/L 0.1% of the EPA limit 1300 µg/L
worst single sample: 1.1 µg/L | 3/3 | SYR4 | 2012–2018 |
| Arsenic | 0.5750 µg/L 5.8% of the EPA limit 10 µg/L
worst single sample: 0.6000 µg/L | 2/3 | SYR4 | 2012–2018 |
| Chromium | 0.7900 µg/L 0.8% of the EPA limit 100 µg/L
worst single sample: 0.8000 µg/L | 2/3 | SYR4 | 2012–2018 |
| Total Haloacetic Acids (HAA5) | 23.2965 µg/L 39% of the EPA limit 60 µg/L
worst single sample: 24.29 µg/L | 2/5 | SYR4 | 2012–2018 |
| Antimony, Total | 0.1000 µg/L 1.7% of the EPA limit 6 µg/L | 1/3 | SYR4 | 2012–2018 |
| Cyanide | 3.1 µg/L 1.6% of the EPA limit 200 µg/L | 1/3 | SYR4 | 2012–2018 |
| Lead | 0.3000 µg/L 2% of the EPA limit 15 µg/L | 1/3 | SYR4 | 2012–2018 |
| Selenium | 2.7 µg/L 5.4% of the EPA limit 50 µg/L | 1/3 | SYR4 | 2012–2018 |
| Thallium, Total | 0.1000 µg/L 5% of the EPA limit 2 µg/L | 1/3 | SYR4 | 2012–2018 |
54 contaminants tested, none detected
Utility contact
Frequently asked questions about Triple T Tampa Mhp
Is Triple T Tampa Mhp tap water safe to drink?
EPA monitoring detected 14 contaminants in Triple T Tampa Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Triple T Tampa Mhp's water?
EPA monitoring detected Lead, Nitrate, Fluoride, TTHM, Barium, and others. The full list with the level and data source for each is above.
How many people does Triple T Tampa Mhp serve?
Triple T Tampa Mhp reports serving 126 people in New Jersey, per its EPA record.
Has Triple T Tampa Mhp had any water quality violations?
The EPA has 70 violations on file for Triple T Tampa Mhp, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.