← Florida

Tap water quality report

River Oaks Utilities, Llc

EPA monitoring tested this supplier for 68 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
11
detected
120
people served
33
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Glades

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

33
health-based violations
184
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2020-04-01 → 2020-06-30
MCL Health-based Resolved 2020-04-01 → 2020-06-30
MCL Health-based Resolved 2020-04-01 → 2020-06-30
MCL Health-based Archived 2007-09-01 → 2007-09-30
MCL Health-based Archived 2007-09-01 → 2007-09-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
19/19 LCR 2024
TTHM
112.912 µg/L 141%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 140 µg/L
9/9 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
137.36 µg/L 229%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 160 µg/L
9/9 SYR4 2012–2019
Fluoride
150 µg/L 3.8%
of the EPA limit 4000 µg/L
worst single sample: 160 µg/L
6/6 SYR4 2012–2018
Barium
26.6 µg/L 1.3%
of the EPA limit 2000 µg/L
worst single sample: 27.1 µg/L
3/3 SYR4 2012–2018
Copper
22.62 µg/L 1.7%
of the EPA limit 1300 µg/L
worst single sample: 23.8 µg/L
3/3 SYR4 2012–2018
Chromium
12.77 µg/L 13%
of the EPA limit 100 µg/L
worst single sample: 14 µg/L
3/3 SYR4 2012–2018
Lead
1.12 µg/L 7.5%
of the EPA limit 15 µg/L
worst single sample: 1.2 µg/L
3/3 SYR4 2012–2018
Cyanide
11.83 µg/L 5.9%
of the EPA limit 200 µg/L
worst single sample: 12.3 µg/L
2/3 SYR4 2012–2018
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2018
Selenium
2.3 µg/L 4.6%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrateNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TERRELL DUKE
Phone
954-680-1404

Frequently asked questions about River Oaks Utilities, Llc

Is River Oaks Utilities, Llc tap water safe to drink?

EPA monitoring detected 11 contaminants in River Oaks Utilities, Llc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in River Oaks Utilities, Llc's water?

EPA monitoring detected Lead, TTHM, Total Haloacetic Acids (HAA5), Fluoride, Barium, and others. The full list with the level and data source for each is above.

How many people does River Oaks Utilities, Llc serve?

River Oaks Utilities, Llc reports serving 120 people in Florida, per its EPA record.

Has River Oaks Utilities, Llc had any water quality violations?

The EPA has 184 violations on file for River Oaks Utilities, Llc, of which 33 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.