← Florida

Tap water quality report

Coral Springs Improvement Dist

EPA monitoring tested this supplier for 98 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
9
detected
40,000
people served
4
health-based violations
Water source
Ground water
Ownership
Mixed public/private
Counties served
Broward

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
140
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-09-01 → 2010-09-30
MCL Health-based Resolved 2010-09-01 → 2010-09-30
MCL Health-based Archived 2009-10-01 → 2009-10-31
MCL Health-based Archived 1994-12-01 → 1994-12-31
MON Monitoring Archived 2026-03-01 → 2026-03-31
MON Monitoring Resolved 2025-08-01 → 2025-08-31
MON Monitoring Archived 2025-07-01 → 2025-07-31
Other Monitoring Unaddressed 2025-07-01
MON Monitoring Archived 2025-06-01 → 2025-06-30
MON Monitoring Archived 2025-05-01 → 2025-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
80 µg/L 100%
of the EPA limit 80 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
60 µg/L 100%
of the EPA limit 60 µg/L
50/57 SYR4 2012–2019
Fluoride
1000 µg/L 25%
of the EPA limit 4000 µg/L
43/43 SYR4 2012–2019
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
21/21 LCR 2023
Barium
5.6 µg/L 0.3%
of the EPA limit 2000 µg/L
6/6 SYR4 2012–2017
Nitrate
170 µg/L 1.7%
of the EPA limit 10000 µg/L
4/16 SYR4 2012–2019
Chromium
1.3 µg/L 1.3%
of the EPA limit 100 µg/L
3/6 SYR4 2012–2017
Copper
2.8 µg/L 0.2%
of the EPA limit 1300 µg/L
2/6 SYR4 2012–2017
Nitrite
160 µg/L 16%
of the EPA limit 1000 µg/L
2/8 SYR4 2012–2019
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DAVID MCINTOSH
Phone
954-796-6665

Frequently asked questions about Coral Springs Improvement Dist

Is Coral Springs Improvement Dist tap water safe to drink?

EPA monitoring detected 9 contaminants in Coral Springs Improvement Dist's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Coral Springs Improvement Dist's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Fluoride, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Coral Springs Improvement Dist serve?

Coral Springs Improvement Dist reports serving 40,000 people in Florida, per its EPA record.

Has Coral Springs Improvement Dist had any water quality violations?

The EPA has 140 violations on file for Coral Springs Improvement Dist, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.